mirror of
https://github.com/Sea-Haven-Industries/open-swe.git
synced 2026-10-07 16:19:09 +00:00
- Add a "Copy markdown" button to the plan header that copies the whole plan. Cross-browser: async Clipboard API in secure contexts, hidden-textarea + execCommand fallback for older Safari/Firefox and non-HTTPS origins. - Fix the conversation banner: it showed "A plan is ready for your review" for every non-approved/cancelled status, including "planning" — so it claimed the plan was ready the instant plan mode began (the agent shares the link early to follow along), then the plan page correctly said it was still being written. Now: planning → "writing a plan", revising → "revising", ready → "ready for your review".
282 lines
9.2 KiB
TypeScript
282 lines
9.2 KiB
TypeScript
import { useCallback, useEffect, useState } from "react"
|
|
|
|
import type { PlanComment, PlanData } from "@/lib/plan"
|
|
import {
|
|
addPlanComment,
|
|
approvePlan,
|
|
deletePlanComment,
|
|
getPlanComments,
|
|
rejectPlan,
|
|
} from "@/lib/plan"
|
|
import { Button } from "@/components/ui/button"
|
|
import { Markdown } from "@/components/agents/ported"
|
|
import { useResolvedTheme } from "@/lib/theme"
|
|
|
|
const POLL_MS = 4000
|
|
|
|
// Copy text to the clipboard across browsers: prefer the async Clipboard API
|
|
// (needs a secure context), and fall back to a hidden-textarea + execCommand
|
|
// for older Safari/Firefox and non-HTTPS origins. Returns whether it copied.
|
|
async function copyToClipboard(text: string): Promise<boolean> {
|
|
// The DOM types mark navigator.clipboard required, but it's absent in older
|
|
// browsers and non-secure origins — treat it as optional.
|
|
const nav = navigator as { clipboard?: Clipboard }
|
|
try {
|
|
if (window.isSecureContext && nav.clipboard) {
|
|
await nav.clipboard.writeText(text)
|
|
return true
|
|
}
|
|
} catch {
|
|
/* fall through to the legacy path */
|
|
}
|
|
try {
|
|
const textarea = document.createElement("textarea")
|
|
textarea.value = text
|
|
textarea.setAttribute("readonly", "")
|
|
textarea.style.position = "fixed"
|
|
textarea.style.top = "-9999px"
|
|
document.body.appendChild(textarea)
|
|
textarea.select()
|
|
textarea.setSelectionRange(0, text.length)
|
|
const ok = document.execCommand("copy")
|
|
document.body.removeChild(textarea)
|
|
return ok
|
|
} catch {
|
|
return false
|
|
}
|
|
}
|
|
|
|
export function PlanReview({ plan }: { plan: PlanData }) {
|
|
const resolvedTheme = useResolvedTheme()
|
|
const [comments, setComments] = useState<Array<PlanComment>>([])
|
|
const [draft, setDraft] = useState("")
|
|
const [posting, setPosting] = useState(false)
|
|
const [decision, setDecision] = useState<string | null>(null)
|
|
const [busy, setBusy] = useState<"approve" | "reject" | null>(null)
|
|
const [error, setError] = useState<string | null>(null)
|
|
const [copied, setCopied] = useState(false)
|
|
|
|
// Poll so reviewers see each other's comments without a realtime transport.
|
|
useEffect(() => {
|
|
let cancelled = false
|
|
const load = async () => {
|
|
try {
|
|
const next = await getPlanComments(plan.threadId)
|
|
if (!cancelled) setComments(next)
|
|
} catch {
|
|
/* transient; next tick retries */
|
|
}
|
|
}
|
|
void load()
|
|
const timer = setInterval(load, POLL_MS)
|
|
return () => {
|
|
cancelled = true
|
|
clearInterval(timer)
|
|
}
|
|
}, [plan.threadId])
|
|
|
|
const submitComment = useCallback(async () => {
|
|
const body = draft.trim()
|
|
if (!body) return
|
|
setPosting(true)
|
|
setError(null)
|
|
try {
|
|
const created = await addPlanComment(plan.threadId, body)
|
|
setComments((prev) => [...prev, created])
|
|
setDraft("")
|
|
} catch (e) {
|
|
setError((e as Error).message)
|
|
} finally {
|
|
setPosting(false)
|
|
}
|
|
}, [draft, plan.threadId])
|
|
|
|
const removeComment = useCallback(
|
|
async (id: string) => {
|
|
try {
|
|
await deletePlanComment(plan.threadId, id)
|
|
setComments((prev) => prev.filter((c) => c.id !== id))
|
|
} catch (e) {
|
|
setError((e as Error).message)
|
|
}
|
|
},
|
|
[plan.threadId]
|
|
)
|
|
|
|
const decide = useCallback(
|
|
async (kind: "approve" | "reject") => {
|
|
setBusy(kind)
|
|
setError(null)
|
|
try {
|
|
if (kind === "approve") await approvePlan(plan.threadId)
|
|
else await rejectPlan(plan.threadId)
|
|
setDecision(
|
|
kind === "approve"
|
|
? "Plan approved — the agent is implementing it."
|
|
: "Changes requested — the agent is revising the plan."
|
|
)
|
|
} catch (e) {
|
|
setError((e as Error).message)
|
|
} finally {
|
|
setBusy(null)
|
|
}
|
|
},
|
|
[plan.threadId]
|
|
)
|
|
|
|
const copyPlan = useCallback(async () => {
|
|
setError(null)
|
|
if (await copyToClipboard(plan.markdown)) {
|
|
setCopied(true)
|
|
window.setTimeout(() => setCopied(false), 1500)
|
|
} else {
|
|
setError("Couldn't copy the plan to the clipboard.")
|
|
}
|
|
}, [plan.markdown])
|
|
|
|
return (
|
|
<div
|
|
data-testid="plan-review"
|
|
className="flex min-h-0 flex-1 flex-col bg-[var(--ui-bg)] text-[var(--ui-text)]"
|
|
>
|
|
<div className="flex items-center justify-between gap-4 border-b border-[var(--ui-border)] px-6 py-3">
|
|
<div>
|
|
<h1 className="text-base font-semibold text-[var(--ui-text)]">
|
|
Implementation plan
|
|
</h1>
|
|
<p className="text-xs text-[var(--ui-text-dim)]">
|
|
Reviewing as {plan.user.name}
|
|
{plan.isOwner ? " (owner)" : ""} · status:{" "}
|
|
<span data-testid="plan-status">{plan.status}</span>
|
|
</p>
|
|
</div>
|
|
<div className="flex shrink-0 items-center gap-2">
|
|
{decision && (
|
|
<span
|
|
data-testid="plan-decision"
|
|
className="text-xs text-[var(--ui-text-dim)]"
|
|
>
|
|
{decision}
|
|
</span>
|
|
)}
|
|
<Button
|
|
data-testid="copy-plan"
|
|
variant="secondary"
|
|
disabled={!plan.markdown.trim()}
|
|
onClick={() => void copyPlan()}
|
|
>
|
|
{copied ? "Copied!" : "Copy markdown"}
|
|
</Button>
|
|
{plan.isOwner && (
|
|
<Button
|
|
data-testid="approve-plan"
|
|
disabled={busy !== null || decision !== null}
|
|
onClick={() => void decide("approve")}
|
|
>
|
|
Approve
|
|
</Button>
|
|
)}
|
|
<Button
|
|
data-testid="reject-plan"
|
|
variant="secondary"
|
|
// Requesting changes feeds the comments to the agent, so it's
|
|
// meaningless with none — disable until at least one is left.
|
|
disabled={busy !== null || decision !== null || comments.length === 0}
|
|
title={
|
|
comments.length === 0
|
|
? "Leave a comment first to request changes"
|
|
: undefined
|
|
}
|
|
onClick={() => void decide("reject")}
|
|
>
|
|
Request changes
|
|
</Button>
|
|
</div>
|
|
</div>
|
|
|
|
<div className="flex min-h-0 flex-1 overflow-hidden">
|
|
<div
|
|
className="min-h-0 flex-1 overflow-auto px-6 py-4"
|
|
data-testid="plan-document"
|
|
data-color-scheme={resolvedTheme}
|
|
>
|
|
{plan.markdown.trim() ? (
|
|
<Markdown content={plan.markdown} />
|
|
) : (
|
|
<p className="text-sm text-[var(--ui-text-dim)]">
|
|
The plan hasn't been written yet.
|
|
</p>
|
|
)}
|
|
</div>
|
|
|
|
<aside className="flex w-80 shrink-0 flex-col border-l border-[var(--ui-border)]">
|
|
<div className="border-b border-[var(--ui-border)] px-4 py-3">
|
|
<h2 className="text-sm font-semibold text-[var(--ui-text)]">
|
|
Comments
|
|
</h2>
|
|
</div>
|
|
<div
|
|
className="min-h-0 flex-1 space-y-3 overflow-auto px-4 py-3"
|
|
data-testid="plan-comments"
|
|
>
|
|
{comments.length === 0 ? (
|
|
<p className="text-xs text-[var(--ui-text-dim)]">
|
|
No comments yet.
|
|
</p>
|
|
) : (
|
|
comments.map((c) => (
|
|
<div
|
|
key={c.id}
|
|
data-testid="plan-comment"
|
|
className="rounded-md border border-[var(--ui-border)] bg-[var(--ui-panel)] px-3 py-2"
|
|
>
|
|
<div className="flex items-center justify-between gap-2">
|
|
<span className="text-xs font-medium text-[var(--ui-text)]">
|
|
{c.author}
|
|
</span>
|
|
<button
|
|
type="button"
|
|
data-testid="comment-delete"
|
|
className="text-xs text-[var(--ui-text-dim)] hover:text-[var(--ui-text)]"
|
|
onClick={() => void removeComment(c.id)}
|
|
>
|
|
Delete
|
|
</button>
|
|
</div>
|
|
<p className="mt-1 text-sm whitespace-pre-wrap text-[var(--ui-text)]">
|
|
{c.body}
|
|
</p>
|
|
</div>
|
|
))
|
|
)}
|
|
</div>
|
|
<div className="border-t border-[var(--ui-border)] p-3">
|
|
{error && (
|
|
<p className="mb-2 text-xs text-[color:var(--ui-danger)]">
|
|
{error}
|
|
</p>
|
|
)}
|
|
<textarea
|
|
data-testid="comment-input"
|
|
value={draft}
|
|
onChange={(e) => setDraft(e.target.value)}
|
|
placeholder="Leave a comment on the plan"
|
|
rows={3}
|
|
className="w-full resize-none rounded-md border border-[var(--ui-border)] bg-[var(--ui-bg)] px-2 py-1.5 text-sm text-[var(--ui-text)] outline-none focus:border-[var(--ui-accent)]"
|
|
/>
|
|
<div className="mt-2 flex justify-end">
|
|
<Button
|
|
data-testid="comment-submit"
|
|
size="sm"
|
|
disabled={posting || !draft.trim()}
|
|
onClick={() => void submitComment()}
|
|
>
|
|
Comment
|
|
</Button>
|
|
</div>
|
|
</div>
|
|
</aside>
|
|
</div>
|
|
</div>
|
|
)
|
|
}
|