refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
import { useCallback, useEffect, useState } from "react"
|
2026-06-29 16:04:41 -04:00
|
|
|
import { useNavigate } from "@tanstack/react-router"
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
import type { PlanComment, PlanData } from "@/lib/plan"
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
import {
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
addPlanComment,
|
|
|
|
|
approvePlan,
|
|
|
|
|
deletePlanComment,
|
|
|
|
|
getPlanComments,
|
|
|
|
|
rejectPlan,
|
2026-06-25 11:21:41 -07:00
|
|
|
updatePlan,
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
} from "@/lib/plan"
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
import { Button } from "@/components/ui/button"
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
import { Markdown } from "@/components/agents/ported"
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
import { useResolvedTheme } from "@/lib/theme"
|
|
|
|
|
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
const POLL_MS = 4000
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
|
2026-06-24 15:07:25 -04:00
|
|
|
// Copy text to the clipboard across browsers: prefer the async Clipboard API
|
|
|
|
|
// (needs a secure context), and fall back to a hidden-textarea + execCommand
|
|
|
|
|
// for older Safari/Firefox and non-HTTPS origins. Returns whether it copied.
|
|
|
|
|
async function copyToClipboard(text: string): Promise<boolean> {
|
|
|
|
|
// The DOM types mark navigator.clipboard required, but it's absent in older
|
|
|
|
|
// browsers and non-secure origins — treat it as optional.
|
|
|
|
|
const nav = navigator as { clipboard?: Clipboard }
|
|
|
|
|
try {
|
|
|
|
|
if (window.isSecureContext && nav.clipboard) {
|
|
|
|
|
await nav.clipboard.writeText(text)
|
|
|
|
|
return true
|
|
|
|
|
}
|
|
|
|
|
} catch {
|
|
|
|
|
/* fall through to the legacy path */
|
|
|
|
|
}
|
|
|
|
|
try {
|
|
|
|
|
const textarea = document.createElement("textarea")
|
|
|
|
|
textarea.value = text
|
|
|
|
|
textarea.setAttribute("readonly", "")
|
|
|
|
|
textarea.style.position = "fixed"
|
|
|
|
|
textarea.style.top = "-9999px"
|
|
|
|
|
document.body.appendChild(textarea)
|
|
|
|
|
textarea.select()
|
|
|
|
|
textarea.setSelectionRange(0, text.length)
|
|
|
|
|
const ok = document.execCommand("copy")
|
|
|
|
|
document.body.removeChild(textarea)
|
|
|
|
|
return ok
|
|
|
|
|
} catch {
|
|
|
|
|
return false
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
export function PlanReview({ plan }: { plan: PlanData }) {
|
2026-06-29 16:04:41 -04:00
|
|
|
const navigate = useNavigate()
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
const resolvedTheme = useResolvedTheme()
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
const [comments, setComments] = useState<Array<PlanComment>>([])
|
|
|
|
|
const [draft, setDraft] = useState("")
|
|
|
|
|
const [posting, setPosting] = useState(false)
|
|
|
|
|
const [decision, setDecision] = useState<string | null>(null)
|
|
|
|
|
const [busy, setBusy] = useState<"approve" | "reject" | null>(null)
|
|
|
|
|
const [error, setError] = useState<string | null>(null)
|
2026-06-24 15:07:25 -04:00
|
|
|
const [copied, setCopied] = useState(false)
|
2026-06-25 11:21:41 -07:00
|
|
|
// Locally track the displayed markdown so a manual edit shows immediately; the
|
|
|
|
|
// route's query stops polling once a plan exists, so the prop won't refetch.
|
|
|
|
|
const [markdown, setMarkdown] = useState(plan.markdown)
|
|
|
|
|
const [editing, setEditing] = useState(false)
|
|
|
|
|
const [editDraft, setEditDraft] = useState(plan.markdown)
|
|
|
|
|
const [saving, setSaving] = useState(false)
|
|
|
|
|
|
|
|
|
|
// Reflect external plan updates (e.g. an agent revision) while not editing.
|
|
|
|
|
useEffect(() => {
|
|
|
|
|
if (!editing) setMarkdown(plan.markdown)
|
|
|
|
|
}, [plan.markdown, editing])
|
|
|
|
|
|
|
|
|
|
const canEdit =
|
|
|
|
|
plan.isOwner && plan.status !== "approved" && plan.status !== "cancelled"
|
|
|
|
|
|
|
|
|
|
const startEditing = useCallback(() => {
|
|
|
|
|
setEditDraft(markdown)
|
|
|
|
|
setEditing(true)
|
|
|
|
|
setError(null)
|
|
|
|
|
}, [markdown])
|
|
|
|
|
|
|
|
|
|
const cancelEditing = useCallback(() => {
|
|
|
|
|
setEditing(false)
|
|
|
|
|
setError(null)
|
|
|
|
|
}, [])
|
|
|
|
|
|
|
|
|
|
const saveEdit = useCallback(async () => {
|
|
|
|
|
const next = editDraft.trim()
|
|
|
|
|
if (!next) {
|
|
|
|
|
setError("The plan cannot be empty.")
|
|
|
|
|
return
|
|
|
|
|
}
|
|
|
|
|
setSaving(true)
|
|
|
|
|
setError(null)
|
|
|
|
|
try {
|
|
|
|
|
const result = await updatePlan(plan.threadId, next)
|
|
|
|
|
setMarkdown(result.markdown)
|
|
|
|
|
setEditing(false)
|
|
|
|
|
} catch (e) {
|
|
|
|
|
setError((e as Error).message)
|
|
|
|
|
} finally {
|
|
|
|
|
setSaving(false)
|
|
|
|
|
}
|
|
|
|
|
}, [editDraft, plan.threadId])
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
// Poll so reviewers see each other's comments without a realtime transport.
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
useEffect(() => {
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
let cancelled = false
|
|
|
|
|
const load = async () => {
|
|
|
|
|
try {
|
|
|
|
|
const next = await getPlanComments(plan.threadId)
|
|
|
|
|
if (!cancelled) setComments(next)
|
|
|
|
|
} catch {
|
|
|
|
|
/* transient; next tick retries */
|
|
|
|
|
}
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
}
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
void load()
|
|
|
|
|
const timer = setInterval(load, POLL_MS)
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
return () => {
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
cancelled = true
|
|
|
|
|
clearInterval(timer)
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
}
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
}, [plan.threadId])
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
const submitComment = useCallback(async () => {
|
|
|
|
|
const body = draft.trim()
|
|
|
|
|
if (!body) return
|
|
|
|
|
setPosting(true)
|
|
|
|
|
setError(null)
|
|
|
|
|
try {
|
|
|
|
|
const created = await addPlanComment(plan.threadId, body)
|
|
|
|
|
setComments((prev) => [...prev, created])
|
|
|
|
|
setDraft("")
|
|
|
|
|
} catch (e) {
|
|
|
|
|
setError((e as Error).message)
|
|
|
|
|
} finally {
|
|
|
|
|
setPosting(false)
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
}
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
}, [draft, plan.threadId])
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
const removeComment = useCallback(
|
|
|
|
|
async (id: string) => {
|
|
|
|
|
try {
|
|
|
|
|
await deletePlanComment(plan.threadId, id)
|
|
|
|
|
setComments((prev) => prev.filter((c) => c.id !== id))
|
|
|
|
|
} catch (e) {
|
|
|
|
|
setError((e as Error).message)
|
|
|
|
|
}
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
},
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
[plan.threadId]
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
)
|
|
|
|
|
|
|
|
|
|
const decide = useCallback(
|
|
|
|
|
async (kind: "approve" | "reject") => {
|
|
|
|
|
setBusy(kind)
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
setError(null)
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
try {
|
2026-06-29 16:04:41 -04:00
|
|
|
if (kind === "approve") {
|
|
|
|
|
await approvePlan(plan.threadId)
|
|
|
|
|
await navigate({
|
|
|
|
|
to: "/agents/$threadId",
|
|
|
|
|
params: { threadId: plan.threadId },
|
|
|
|
|
})
|
|
|
|
|
return
|
|
|
|
|
}
|
|
|
|
|
await rejectPlan(plan.threadId)
|
|
|
|
|
setDecision("Changes requested — the agent is revising the plan.")
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
} catch (e) {
|
|
|
|
|
setError((e as Error).message)
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
} finally {
|
|
|
|
|
setBusy(null)
|
|
|
|
|
}
|
|
|
|
|
},
|
2026-06-29 16:04:41 -04:00
|
|
|
[navigate, plan.threadId]
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
)
|
|
|
|
|
|
2026-06-24 15:07:25 -04:00
|
|
|
const copyPlan = useCallback(async () => {
|
|
|
|
|
setError(null)
|
2026-06-25 11:21:41 -07:00
|
|
|
if (await copyToClipboard(markdown)) {
|
2026-06-24 15:07:25 -04:00
|
|
|
setCopied(true)
|
|
|
|
|
window.setTimeout(() => setCopied(false), 1500)
|
|
|
|
|
} else {
|
|
|
|
|
setError("Couldn't copy the plan to the clipboard.")
|
|
|
|
|
}
|
2026-06-25 11:21:41 -07:00
|
|
|
}, [markdown])
|
2026-06-24 15:07:25 -04:00
|
|
|
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
return (
|
|
|
|
|
<div
|
|
|
|
|
data-testid="plan-review"
|
|
|
|
|
className="flex min-h-0 flex-1 flex-col bg-[var(--ui-bg)] text-[var(--ui-text)]"
|
|
|
|
|
>
|
2026-06-29 09:37:16 -07:00
|
|
|
<div className="flex flex-col gap-3 border-b border-[var(--ui-border)] px-4 py-3 md:flex-row md:items-center md:justify-between md:gap-4 md:px-6">
|
|
|
|
|
<div className="min-w-0">
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
<h1 className="text-base font-semibold text-[var(--ui-text)]">
|
|
|
|
|
Implementation plan
|
|
|
|
|
</h1>
|
|
|
|
|
<p className="text-xs text-[var(--ui-text-dim)]">
|
|
|
|
|
Reviewing as {plan.user.name}
|
|
|
|
|
{plan.isOwner ? " (owner)" : ""} · status:{" "}
|
|
|
|
|
<span data-testid="plan-status">{plan.status}</span>
|
|
|
|
|
</p>
|
|
|
|
|
</div>
|
2026-06-29 09:37:16 -07:00
|
|
|
<div className="flex min-w-0 flex-wrap items-center gap-2 md:shrink-0 md:justify-end">
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
{decision && (
|
|
|
|
|
<span
|
|
|
|
|
data-testid="plan-decision"
|
2026-06-29 09:37:16 -07:00
|
|
|
className="w-full text-xs text-[var(--ui-text-dim)] md:w-auto"
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
>
|
|
|
|
|
{decision}
|
|
|
|
|
</span>
|
|
|
|
|
)}
|
2026-06-25 11:21:41 -07:00
|
|
|
{editing ? (
|
|
|
|
|
<>
|
|
|
|
|
<Button
|
|
|
|
|
data-testid="cancel-edit-plan"
|
|
|
|
|
variant="secondary"
|
|
|
|
|
disabled={saving}
|
|
|
|
|
onClick={cancelEditing}
|
|
|
|
|
>
|
|
|
|
|
Cancel
|
|
|
|
|
</Button>
|
|
|
|
|
<Button
|
|
|
|
|
data-testid="save-plan"
|
|
|
|
|
disabled={saving || !editDraft.trim()}
|
|
|
|
|
onClick={() => void saveEdit()}
|
|
|
|
|
>
|
|
|
|
|
{saving ? "Saving…" : "Save"}
|
|
|
|
|
</Button>
|
|
|
|
|
</>
|
|
|
|
|
) : (
|
|
|
|
|
<>
|
|
|
|
|
{canEdit && (
|
|
|
|
|
<Button
|
|
|
|
|
data-testid="edit-plan"
|
|
|
|
|
variant="secondary"
|
|
|
|
|
disabled={busy !== null || decision !== null}
|
|
|
|
|
onClick={startEditing}
|
|
|
|
|
>
|
|
|
|
|
Edit
|
|
|
|
|
</Button>
|
|
|
|
|
)}
|
|
|
|
|
<Button
|
|
|
|
|
data-testid="copy-plan"
|
|
|
|
|
variant="secondary"
|
|
|
|
|
disabled={!markdown.trim()}
|
|
|
|
|
onClick={() => void copyPlan()}
|
|
|
|
|
>
|
|
|
|
|
{copied ? "Copied!" : "Copy markdown"}
|
|
|
|
|
</Button>
|
|
|
|
|
{plan.isOwner && (
|
|
|
|
|
<Button
|
|
|
|
|
data-testid="approve-plan"
|
|
|
|
|
disabled={busy !== null || decision !== null}
|
|
|
|
|
onClick={() => void decide("approve")}
|
|
|
|
|
>
|
|
|
|
|
Approve
|
|
|
|
|
</Button>
|
|
|
|
|
)}
|
|
|
|
|
<Button
|
|
|
|
|
data-testid="reject-plan"
|
|
|
|
|
variant="secondary"
|
|
|
|
|
// Requesting changes feeds the comments to the agent, so it's
|
|
|
|
|
// meaningless with none — disable until at least one is left.
|
|
|
|
|
disabled={
|
|
|
|
|
busy !== null || decision !== null || comments.length === 0
|
|
|
|
|
}
|
|
|
|
|
title={
|
|
|
|
|
comments.length === 0
|
|
|
|
|
? "Leave a comment first to request changes"
|
|
|
|
|
: undefined
|
|
|
|
|
}
|
|
|
|
|
onClick={() => void decide("reject")}
|
|
|
|
|
>
|
|
|
|
|
Request changes
|
|
|
|
|
</Button>
|
|
|
|
|
</>
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
)}
|
|
|
|
|
</div>
|
|
|
|
|
</div>
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
|
2026-06-29 09:37:16 -07:00
|
|
|
<div className="flex min-h-0 flex-1 flex-col overflow-y-auto md:flex-row md:overflow-hidden">
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
<div
|
2026-06-29 09:37:16 -07:00
|
|
|
className="min-w-0 px-4 py-4 md:min-h-0 md:flex-1 md:overflow-auto md:px-6"
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
data-testid="plan-document"
|
|
|
|
|
data-color-scheme={resolvedTheme}
|
|
|
|
|
>
|
2026-06-25 11:21:41 -07:00
|
|
|
{editing ? (
|
|
|
|
|
<div className="flex h-full flex-col gap-2">
|
|
|
|
|
{error && (
|
|
|
|
|
<p className="text-xs text-[color:var(--ui-danger)]">{error}</p>
|
|
|
|
|
)}
|
|
|
|
|
<textarea
|
|
|
|
|
data-testid="plan-editor"
|
|
|
|
|
value={editDraft}
|
|
|
|
|
onChange={(e) => setEditDraft(e.target.value)}
|
|
|
|
|
spellCheck={false}
|
|
|
|
|
className="min-h-[20rem] w-full flex-1 resize-none rounded-md border border-[var(--ui-border)] bg-[var(--ui-bg)] px-3 py-2 font-mono text-sm text-[var(--ui-text)] outline-none focus:border-[var(--ui-accent)]"
|
|
|
|
|
/>
|
|
|
|
|
</div>
|
|
|
|
|
) : markdown.trim() ? (
|
|
|
|
|
<Markdown content={markdown} />
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
) : (
|
|
|
|
|
<p className="text-sm text-[var(--ui-text-dim)]">
|
|
|
|
|
The plan hasn't been written yet.
|
|
|
|
|
</p>
|
|
|
|
|
)}
|
|
|
|
|
</div>
|
|
|
|
|
|
2026-06-29 09:37:16 -07:00
|
|
|
<aside className="flex shrink-0 flex-col border-t border-[var(--ui-border)] md:w-80 md:border-t-0 md:border-l">
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
<div className="border-b border-[var(--ui-border)] px-4 py-3">
|
|
|
|
|
<h2 className="text-sm font-semibold text-[var(--ui-text)]">
|
|
|
|
|
Comments
|
|
|
|
|
</h2>
|
|
|
|
|
</div>
|
|
|
|
|
<div
|
2026-06-29 09:37:16 -07:00
|
|
|
className="max-h-80 space-y-3 overflow-auto px-4 py-3 md:max-h-none md:min-h-0 md:flex-1"
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
data-testid="plan-comments"
|
|
|
|
|
>
|
|
|
|
|
{comments.length === 0 ? (
|
|
|
|
|
<p className="text-xs text-[var(--ui-text-dim)]">
|
|
|
|
|
No comments yet.
|
|
|
|
|
</p>
|
|
|
|
|
) : (
|
|
|
|
|
comments.map((c) => (
|
|
|
|
|
<div
|
|
|
|
|
key={c.id}
|
|
|
|
|
data-testid="plan-comment"
|
|
|
|
|
className="rounded-md border border-[var(--ui-border)] bg-[var(--ui-panel)] px-3 py-2"
|
|
|
|
|
>
|
|
|
|
|
<div className="flex items-center justify-between gap-2">
|
|
|
|
|
<span className="text-xs font-medium text-[var(--ui-text)]">
|
|
|
|
|
{c.author}
|
|
|
|
|
</span>
|
|
|
|
|
<button
|
|
|
|
|
type="button"
|
|
|
|
|
data-testid="comment-delete"
|
|
|
|
|
className="text-xs text-[var(--ui-text-dim)] hover:text-[var(--ui-text)]"
|
|
|
|
|
onClick={() => void removeComment(c.id)}
|
|
|
|
|
>
|
|
|
|
|
Delete
|
|
|
|
|
</button>
|
|
|
|
|
</div>
|
|
|
|
|
<p className="mt-1 text-sm whitespace-pre-wrap text-[var(--ui-text)]">
|
|
|
|
|
{c.body}
|
|
|
|
|
</p>
|
|
|
|
|
</div>
|
|
|
|
|
))
|
|
|
|
|
)}
|
|
|
|
|
</div>
|
|
|
|
|
<div className="border-t border-[var(--ui-border)] p-3">
|
|
|
|
|
{error && (
|
|
|
|
|
<p className="mb-2 text-xs text-[color:var(--ui-danger)]">
|
|
|
|
|
{error}
|
|
|
|
|
</p>
|
|
|
|
|
)}
|
|
|
|
|
<textarea
|
|
|
|
|
data-testid="comment-input"
|
|
|
|
|
value={draft}
|
|
|
|
|
onChange={(e) => setDraft(e.target.value)}
|
|
|
|
|
placeholder="Leave a comment on the plan"
|
|
|
|
|
rows={3}
|
|
|
|
|
className="w-full resize-none rounded-md border border-[var(--ui-border)] bg-[var(--ui-bg)] px-2 py-1.5 text-sm text-[var(--ui-text)] outline-none focus:border-[var(--ui-accent)]"
|
|
|
|
|
/>
|
|
|
|
|
<div className="mt-2 flex justify-end">
|
|
|
|
|
<Button
|
|
|
|
|
data-testid="comment-submit"
|
|
|
|
|
size="sm"
|
|
|
|
|
disabled={posting || !draft.trim()}
|
|
|
|
|
onClick={() => void submitComment()}
|
|
|
|
|
>
|
|
|
|
|
Comment
|
|
|
|
|
</Button>
|
|
|
|
|
</div>
|
|
|
|
|
</div>
|
|
|
|
|
</aside>
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
</div>
|
|
|
|
|
</div>
|
|
|
|
|
)
|
|
|
|
|
}
|