feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
import { type KeyboardEvent, useCallback, useEffect, useState } from "react"
|
chore: cherry-pick clean upstream fixes + cherry-pick runbook (#117)
* fix: make plan view mobile friendly (#1636)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 7ee3e0572406359632502b0d65450709a03645ea)
* fix: return to thread after plan approval (#1637)
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit f32e492ab46c120130e0c63eeca3eb353f10d83e)
* feat: reviews block agenda, sticky headers, accurate diff scroll (#1653)
Rework the AI-sorted blocks experience on the PR reviews page into a
Google-Docs-style outline: the left sidebar is now a clean number+title
agenda with scroll-spy highlighting of the active block; each block shows
its title + description (sticky) above its diff; and diff rows are pinned to
a uniform height so scroll-to lands precisely via the virtualizer's own
geometry instead of an estimate-driven correction loop.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 0b76afdc955e33805c7623d1502a75a9c7c9c1b7)
* fix: jump + ResizeObserver settle for review scroll-to (#1655)
Replace smooth-scroll plus frame-count correction loops on the PR
reviews page with an instant jump that re-asserts its target via a
ResizeObserver (the real "layout settled" signal). Block/file
navigation and finding/comment centering now land deterministically as
off-screen cards mount, files expand, and annotation cards measure,
instead of racing a smooth-scroll animation against height
reconciliation. Holds bail on user wheel/touch input and after a short
ceiling, and a new navigation cancels the previous hold.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
(cherry picked from commit 7530653bba7774d66a54b8bef0d2bbc25f519942)
* fix: purge expired thread_wakeup crons (#1656)
* fix: purge expired thread_wakeup crons
One-shot wakeup crons set an end_time that stops re-firing but the cron
row is never deleted, so dead rows accumulate (86 in prod). Add a purge
that deletes thread_wakeup crons past their end_time, called
opportunistically before scheduling a new wakeup, plus a one-time
backfill script. Conservative: matches only kind=thread_wakeup with a
past end_time.
* chore: retrigger Open SWE review
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 9e5a1924ef306269322c31342a1831e57831cfee)
* fix: add top padding to sticky review block header (#1660)
* fix: add top padding to sticky review block header
The sticky per-block header on the reviews page had padding below but
none above, so the block number badge sat glued against the top edge
when pinned. Add matching top padding for breathing room.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* chore: use py-2 shorthand for review block header padding
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 23bd4a63fc5ba0fe853babf79ed33feb866cc8b2)
* fix: use global tokens for sidebar filter popover border (#1661)
The filter popover renders via base-ui Menu.Portal into document.body,
outside the .agents-ui container where the --ui-* CSS variables are
scoped. As a result border-[var(--ui-border)] resolved to an undefined
variable and border-color fell back to currentColor, producing a strong
near-black border (separators/hover/labels were similarly off).
Switch the portaled popup styling to the same global shadcn tokens the
theme/settings popover (SidebarUserMenu) already uses (border-border,
bg-border, bg-muted, text-muted-foreground). These are defined at :root
so they resolve inside portals too, and match the settings popover.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 63eb9a08209f683016abf01cdcc548bc5905f158)
* fix: preserve dashboard redirect after login (#1668)
* fix: preserve dashboard redirect after login
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: cover plan login redirect in e2e
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit bc7ce59169b5350da7286164afb83a7b037b528d)
* Disable React StrictMode (#1654)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 6575c327a3ac2b107a6e79a04fa61168d779dbf0)
* docs(upstream-sync): add cherry-pick runbook
Repo-specific runbook for bringing upstream (langchain-ai/open-swe) commits
into the fork: triage-sync discovery, the git cp workflow, the triage ledger,
themed-branch layout, and conflict/regression handling.
---------
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Ramon Nogueira <ramon.nogueira@langchain.dev>
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: Caroline di Vittorio <43390382+carolinedivittorio@users.noreply.github.com>
2026-07-03 11:48:40 -04:00
|
|
|
import { useNavigate } from "@tanstack/react-router"
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
import type { PlanComment, PlanData } from "@/lib/plan"
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
import {
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
addPlanComment,
|
|
|
|
|
approvePlan,
|
|
|
|
|
deletePlanComment,
|
|
|
|
|
getPlanComments,
|
|
|
|
|
rejectPlan,
|
feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80) (#130)
* feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80)
Adds a PUT /dashboard/api/plan/{thread_id} endpoint and PlanReview UI edit
mode so the thread owner can refine the published plan markdown by hand. The
edited markdown is re-published as "ready" (preserving reviewer comments),
mirrored into the sandbox plan.md, and handed to the agent as the source of
truth on approve.
Approve now reads the published plan content strictly (raise_on_error=True)
so a transient store failure aborts instead of silently dropping an edited
plan, matching the comment-read contract.
The banner-overlap fix (collapsed git-panel clearing the "Review plan" link)
was already ported in #128; this picks up the remaining edit-mode pieces.
Refs #80
* fix(plan): make approve_plan idempotent, dispatch before persisting, fix comment count
SH-128-03: approve_plan set status APPROVED before dispatching the follow-up
run and had no already-approved guard, so a failed dispatch left the plan stuck
approved-but-undispatched and a double-submit double-dispatched + double-posted
the Slack notice. And the Slack notice counted len(comments) including empty
comments _format_comments filters out.
- Return 409 when the plan is already approved (idempotent double-click/retry).
- Dispatch the implementation run BEFORE persisting APPROVED so a dispatch
failure leaves the plan re-approvable. _dispatch_followup passes plan_mode
explicitly, so the run is unaffected by the reorder.
- Count only non-empty comments in the Slack approval notice.
Fixed here (not on #128) because #128's approve_plan is rewritten on this
branch; #129 inherits it. Adds tests for the 409, the filtered count, and the
dispatch-before-status ordering.
---------
Co-authored-by: seahaven-openswe[bot] <296972425+seahaven-openswe[bot]@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-08 18:44:56 -04:00
|
|
|
updatePlan,
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
} from "@/lib/plan"
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
import { Button } from "@/components/ui/button"
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
import { Markdown } from "@/components/agents/ported"
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
import { useResolvedTheme } from "@/lib/theme"
|
|
|
|
|
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
const POLL_MS = 4000
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
|
2026-06-24 15:07:25 -04:00
|
|
|
// Copy text to the clipboard across browsers: prefer the async Clipboard API
|
|
|
|
|
// (needs a secure context), and fall back to a hidden-textarea + execCommand
|
|
|
|
|
// for older Safari/Firefox and non-HTTPS origins. Returns whether it copied.
|
|
|
|
|
async function copyToClipboard(text: string): Promise<boolean> {
|
|
|
|
|
// The DOM types mark navigator.clipboard required, but it's absent in older
|
|
|
|
|
// browsers and non-secure origins — treat it as optional.
|
|
|
|
|
const nav = navigator as { clipboard?: Clipboard }
|
|
|
|
|
try {
|
|
|
|
|
if (window.isSecureContext && nav.clipboard) {
|
|
|
|
|
await nav.clipboard.writeText(text)
|
|
|
|
|
return true
|
|
|
|
|
}
|
|
|
|
|
} catch {
|
|
|
|
|
/* fall through to the legacy path */
|
|
|
|
|
}
|
|
|
|
|
try {
|
|
|
|
|
const textarea = document.createElement("textarea")
|
|
|
|
|
textarea.value = text
|
|
|
|
|
textarea.setAttribute("readonly", "")
|
|
|
|
|
textarea.style.position = "fixed"
|
|
|
|
|
textarea.style.top = "-9999px"
|
|
|
|
|
document.body.appendChild(textarea)
|
|
|
|
|
textarea.select()
|
|
|
|
|
textarea.setSelectionRange(0, text.length)
|
|
|
|
|
const ok = document.execCommand("copy")
|
|
|
|
|
document.body.removeChild(textarea)
|
|
|
|
|
return ok
|
|
|
|
|
} catch {
|
|
|
|
|
return false
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
export function PlanReview({ plan }: { plan: PlanData }) {
|
chore: cherry-pick clean upstream fixes + cherry-pick runbook (#117)
* fix: make plan view mobile friendly (#1636)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 7ee3e0572406359632502b0d65450709a03645ea)
* fix: return to thread after plan approval (#1637)
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit f32e492ab46c120130e0c63eeca3eb353f10d83e)
* feat: reviews block agenda, sticky headers, accurate diff scroll (#1653)
Rework the AI-sorted blocks experience on the PR reviews page into a
Google-Docs-style outline: the left sidebar is now a clean number+title
agenda with scroll-spy highlighting of the active block; each block shows
its title + description (sticky) above its diff; and diff rows are pinned to
a uniform height so scroll-to lands precisely via the virtualizer's own
geometry instead of an estimate-driven correction loop.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 0b76afdc955e33805c7623d1502a75a9c7c9c1b7)
* fix: jump + ResizeObserver settle for review scroll-to (#1655)
Replace smooth-scroll plus frame-count correction loops on the PR
reviews page with an instant jump that re-asserts its target via a
ResizeObserver (the real "layout settled" signal). Block/file
navigation and finding/comment centering now land deterministically as
off-screen cards mount, files expand, and annotation cards measure,
instead of racing a smooth-scroll animation against height
reconciliation. Holds bail on user wheel/touch input and after a short
ceiling, and a new navigation cancels the previous hold.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
(cherry picked from commit 7530653bba7774d66a54b8bef0d2bbc25f519942)
* fix: purge expired thread_wakeup crons (#1656)
* fix: purge expired thread_wakeup crons
One-shot wakeup crons set an end_time that stops re-firing but the cron
row is never deleted, so dead rows accumulate (86 in prod). Add a purge
that deletes thread_wakeup crons past their end_time, called
opportunistically before scheduling a new wakeup, plus a one-time
backfill script. Conservative: matches only kind=thread_wakeup with a
past end_time.
* chore: retrigger Open SWE review
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 9e5a1924ef306269322c31342a1831e57831cfee)
* fix: add top padding to sticky review block header (#1660)
* fix: add top padding to sticky review block header
The sticky per-block header on the reviews page had padding below but
none above, so the block number badge sat glued against the top edge
when pinned. Add matching top padding for breathing room.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* chore: use py-2 shorthand for review block header padding
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 23bd4a63fc5ba0fe853babf79ed33feb866cc8b2)
* fix: use global tokens for sidebar filter popover border (#1661)
The filter popover renders via base-ui Menu.Portal into document.body,
outside the .agents-ui container where the --ui-* CSS variables are
scoped. As a result border-[var(--ui-border)] resolved to an undefined
variable and border-color fell back to currentColor, producing a strong
near-black border (separators/hover/labels were similarly off).
Switch the portaled popup styling to the same global shadcn tokens the
theme/settings popover (SidebarUserMenu) already uses (border-border,
bg-border, bg-muted, text-muted-foreground). These are defined at :root
so they resolve inside portals too, and match the settings popover.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 63eb9a08209f683016abf01cdcc548bc5905f158)
* fix: preserve dashboard redirect after login (#1668)
* fix: preserve dashboard redirect after login
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: cover plan login redirect in e2e
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit bc7ce59169b5350da7286164afb83a7b037b528d)
* Disable React StrictMode (#1654)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 6575c327a3ac2b107a6e79a04fa61168d779dbf0)
* docs(upstream-sync): add cherry-pick runbook
Repo-specific runbook for bringing upstream (langchain-ai/open-swe) commits
into the fork: triage-sync discovery, the git cp workflow, the triage ledger,
themed-branch layout, and conflict/regression handling.
---------
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Ramon Nogueira <ramon.nogueira@langchain.dev>
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: Caroline di Vittorio <43390382+carolinedivittorio@users.noreply.github.com>
2026-07-03 11:48:40 -04:00
|
|
|
const navigate = useNavigate()
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
const resolvedTheme = useResolvedTheme()
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
const [comments, setComments] = useState<Array<PlanComment>>([])
|
|
|
|
|
const [draft, setDraft] = useState("")
|
|
|
|
|
const [posting, setPosting] = useState(false)
|
|
|
|
|
const [decision, setDecision] = useState<string | null>(null)
|
|
|
|
|
const [busy, setBusy] = useState<"approve" | "reject" | null>(null)
|
|
|
|
|
const [error, setError] = useState<string | null>(null)
|
2026-06-24 15:07:25 -04:00
|
|
|
const [copied, setCopied] = useState(false)
|
feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80) (#130)
* feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80)
Adds a PUT /dashboard/api/plan/{thread_id} endpoint and PlanReview UI edit
mode so the thread owner can refine the published plan markdown by hand. The
edited markdown is re-published as "ready" (preserving reviewer comments),
mirrored into the sandbox plan.md, and handed to the agent as the source of
truth on approve.
Approve now reads the published plan content strictly (raise_on_error=True)
so a transient store failure aborts instead of silently dropping an edited
plan, matching the comment-read contract.
The banner-overlap fix (collapsed git-panel clearing the "Review plan" link)
was already ported in #128; this picks up the remaining edit-mode pieces.
Refs #80
* fix(plan): make approve_plan idempotent, dispatch before persisting, fix comment count
SH-128-03: approve_plan set status APPROVED before dispatching the follow-up
run and had no already-approved guard, so a failed dispatch left the plan stuck
approved-but-undispatched and a double-submit double-dispatched + double-posted
the Slack notice. And the Slack notice counted len(comments) including empty
comments _format_comments filters out.
- Return 409 when the plan is already approved (idempotent double-click/retry).
- Dispatch the implementation run BEFORE persisting APPROVED so a dispatch
failure leaves the plan re-approvable. _dispatch_followup passes plan_mode
explicitly, so the run is unaffected by the reorder.
- Count only non-empty comments in the Slack approval notice.
Fixed here (not on #128) because #128's approve_plan is rewritten on this
branch; #129 inherits it. Adds tests for the 409, the filtered count, and the
dispatch-before-status ordering.
---------
Co-authored-by: seahaven-openswe[bot] <296972425+seahaven-openswe[bot]@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-08 18:44:56 -04:00
|
|
|
// Locally track the displayed markdown so a manual edit shows immediately; the
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
// route's query stops polling once content exists, so the prop won't refetch.
|
feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80) (#130)
* feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80)
Adds a PUT /dashboard/api/plan/{thread_id} endpoint and PlanReview UI edit
mode so the thread owner can refine the published plan markdown by hand. The
edited markdown is re-published as "ready" (preserving reviewer comments),
mirrored into the sandbox plan.md, and handed to the agent as the source of
truth on approve.
Approve now reads the published plan content strictly (raise_on_error=True)
so a transient store failure aborts instead of silently dropping an edited
plan, matching the comment-read contract.
The banner-overlap fix (collapsed git-panel clearing the "Review plan" link)
was already ported in #128; this picks up the remaining edit-mode pieces.
Refs #80
* fix(plan): make approve_plan idempotent, dispatch before persisting, fix comment count
SH-128-03: approve_plan set status APPROVED before dispatching the follow-up
run and had no already-approved guard, so a failed dispatch left the plan stuck
approved-but-undispatched and a double-submit double-dispatched + double-posted
the Slack notice. And the Slack notice counted len(comments) including empty
comments _format_comments filters out.
- Return 409 when the plan is already approved (idempotent double-click/retry).
- Dispatch the implementation run BEFORE persisting APPROVED so a dispatch
failure leaves the plan re-approvable. _dispatch_followup passes plan_mode
explicitly, so the run is unaffected by the reorder.
- Count only non-empty comments in the Slack approval notice.
Fixed here (not on #128) because #128's approve_plan is rewritten on this
branch; #129 inherits it. Adds tests for the 409, the filtered count, and the
dispatch-before-status ordering.
---------
Co-authored-by: seahaven-openswe[bot] <296972425+seahaven-openswe[bot]@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-08 18:44:56 -04:00
|
|
|
const [markdown, setMarkdown] = useState(plan.markdown)
|
|
|
|
|
const [editing, setEditing] = useState(false)
|
|
|
|
|
const [editDraft, setEditDraft] = useState(plan.markdown)
|
|
|
|
|
const [saving, setSaving] = useState(false)
|
|
|
|
|
|
|
|
|
|
// Reflect external plan updates (e.g. an agent revision) while not editing.
|
|
|
|
|
useEffect(() => {
|
|
|
|
|
if (!editing) setMarkdown(plan.markdown)
|
|
|
|
|
}, [plan.markdown, editing])
|
|
|
|
|
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
const isShared = plan.status === "shared"
|
feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80) (#130)
* feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80)
Adds a PUT /dashboard/api/plan/{thread_id} endpoint and PlanReview UI edit
mode so the thread owner can refine the published plan markdown by hand. The
edited markdown is re-published as "ready" (preserving reviewer comments),
mirrored into the sandbox plan.md, and handed to the agent as the source of
truth on approve.
Approve now reads the published plan content strictly (raise_on_error=True)
so a transient store failure aborts instead of silently dropping an edited
plan, matching the comment-read contract.
The banner-overlap fix (collapsed git-panel clearing the "Review plan" link)
was already ported in #128; this picks up the remaining edit-mode pieces.
Refs #80
* fix(plan): make approve_plan idempotent, dispatch before persisting, fix comment count
SH-128-03: approve_plan set status APPROVED before dispatching the follow-up
run and had no already-approved guard, so a failed dispatch left the plan stuck
approved-but-undispatched and a double-submit double-dispatched + double-posted
the Slack notice. And the Slack notice counted len(comments) including empty
comments _format_comments filters out.
- Return 409 when the plan is already approved (idempotent double-click/retry).
- Dispatch the implementation run BEFORE persisting APPROVED so a dispatch
failure leaves the plan re-approvable. _dispatch_followup passes plan_mode
explicitly, so the run is unaffected by the reorder.
- Count only non-empty comments in the Slack approval notice.
Fixed here (not on #128) because #128's approve_plan is rewritten on this
branch; #129 inherits it. Adds tests for the 409, the filtered count, and the
dispatch-before-status ordering.
---------
Co-authored-by: seahaven-openswe[bot] <296972425+seahaven-openswe[bot]@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-08 18:44:56 -04:00
|
|
|
const canEdit =
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
plan.isOwner &&
|
|
|
|
|
!isShared &&
|
|
|
|
|
plan.status !== "approved" &&
|
|
|
|
|
plan.status !== "cancelled"
|
feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80) (#130)
* feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80)
Adds a PUT /dashboard/api/plan/{thread_id} endpoint and PlanReview UI edit
mode so the thread owner can refine the published plan markdown by hand. The
edited markdown is re-published as "ready" (preserving reviewer comments),
mirrored into the sandbox plan.md, and handed to the agent as the source of
truth on approve.
Approve now reads the published plan content strictly (raise_on_error=True)
so a transient store failure aborts instead of silently dropping an edited
plan, matching the comment-read contract.
The banner-overlap fix (collapsed git-panel clearing the "Review plan" link)
was already ported in #128; this picks up the remaining edit-mode pieces.
Refs #80
* fix(plan): make approve_plan idempotent, dispatch before persisting, fix comment count
SH-128-03: approve_plan set status APPROVED before dispatching the follow-up
run and had no already-approved guard, so a failed dispatch left the plan stuck
approved-but-undispatched and a double-submit double-dispatched + double-posted
the Slack notice. And the Slack notice counted len(comments) including empty
comments _format_comments filters out.
- Return 409 when the plan is already approved (idempotent double-click/retry).
- Dispatch the implementation run BEFORE persisting APPROVED so a dispatch
failure leaves the plan re-approvable. _dispatch_followup passes plan_mode
explicitly, so the run is unaffected by the reorder.
- Count only non-empty comments in the Slack approval notice.
Fixed here (not on #128) because #128's approve_plan is rewritten on this
branch; #129 inherits it. Adds tests for the 409, the filtered count, and the
dispatch-before-status ordering.
---------
Co-authored-by: seahaven-openswe[bot] <296972425+seahaven-openswe[bot]@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-08 18:44:56 -04:00
|
|
|
|
|
|
|
|
const startEditing = useCallback(() => {
|
|
|
|
|
setEditDraft(markdown)
|
|
|
|
|
setEditing(true)
|
|
|
|
|
setError(null)
|
|
|
|
|
}, [markdown])
|
|
|
|
|
|
|
|
|
|
const cancelEditing = useCallback(() => {
|
|
|
|
|
setEditing(false)
|
|
|
|
|
setError(null)
|
|
|
|
|
}, [])
|
|
|
|
|
|
|
|
|
|
const saveEdit = useCallback(async () => {
|
|
|
|
|
const next = editDraft.trim()
|
|
|
|
|
if (!next) {
|
|
|
|
|
setError("The plan cannot be empty.")
|
|
|
|
|
return
|
|
|
|
|
}
|
|
|
|
|
setSaving(true)
|
|
|
|
|
setError(null)
|
|
|
|
|
try {
|
|
|
|
|
const result = await updatePlan(plan.threadId, next)
|
|
|
|
|
setMarkdown(result.markdown)
|
|
|
|
|
setEditing(false)
|
|
|
|
|
} catch (e) {
|
|
|
|
|
setError((e as Error).message)
|
|
|
|
|
} finally {
|
|
|
|
|
setSaving(false)
|
|
|
|
|
}
|
|
|
|
|
}, [editDraft, plan.threadId])
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
// Poll so reviewers see each other's comments without a realtime transport.
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
useEffect(() => {
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
let cancelled = false
|
|
|
|
|
const load = async () => {
|
|
|
|
|
try {
|
|
|
|
|
const next = await getPlanComments(plan.threadId)
|
|
|
|
|
if (!cancelled) setComments(next)
|
|
|
|
|
} catch {
|
|
|
|
|
/* transient; next tick retries */
|
|
|
|
|
}
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
}
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
if (isShared) return
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
void load()
|
|
|
|
|
const timer = setInterval(load, POLL_MS)
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
return () => {
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
cancelled = true
|
|
|
|
|
clearInterval(timer)
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
}
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
}, [isShared, plan.threadId])
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
const submitComment = useCallback(async () => {
|
|
|
|
|
const body = draft.trim()
|
|
|
|
|
if (!body) return
|
|
|
|
|
setPosting(true)
|
|
|
|
|
setError(null)
|
|
|
|
|
try {
|
|
|
|
|
const created = await addPlanComment(plan.threadId, body)
|
|
|
|
|
setComments((prev) => [...prev, created])
|
|
|
|
|
setDraft("")
|
|
|
|
|
} catch (e) {
|
|
|
|
|
setError((e as Error).message)
|
|
|
|
|
} finally {
|
|
|
|
|
setPosting(false)
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
}
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
}, [draft, plan.threadId])
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
const handleCommentKeyDown = useCallback(
|
|
|
|
|
(event: KeyboardEvent<HTMLTextAreaElement>) => {
|
|
|
|
|
if (event.key !== "Enter" || (!event.metaKey && !event.ctrlKey)) return
|
|
|
|
|
event.preventDefault()
|
|
|
|
|
if (posting || !draft.trim()) return
|
|
|
|
|
void submitComment()
|
|
|
|
|
},
|
|
|
|
|
[draft, posting, submitComment]
|
|
|
|
|
)
|
|
|
|
|
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
const removeComment = useCallback(
|
|
|
|
|
async (id: string) => {
|
|
|
|
|
try {
|
|
|
|
|
await deletePlanComment(plan.threadId, id)
|
|
|
|
|
setComments((prev) => prev.filter((c) => c.id !== id))
|
|
|
|
|
} catch (e) {
|
|
|
|
|
setError((e as Error).message)
|
|
|
|
|
}
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
},
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
[plan.threadId]
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
)
|
|
|
|
|
|
|
|
|
|
const decide = useCallback(
|
|
|
|
|
async (kind: "approve" | "reject") => {
|
|
|
|
|
setBusy(kind)
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
setError(null)
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
try {
|
chore: cherry-pick clean upstream fixes + cherry-pick runbook (#117)
* fix: make plan view mobile friendly (#1636)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 7ee3e0572406359632502b0d65450709a03645ea)
* fix: return to thread after plan approval (#1637)
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit f32e492ab46c120130e0c63eeca3eb353f10d83e)
* feat: reviews block agenda, sticky headers, accurate diff scroll (#1653)
Rework the AI-sorted blocks experience on the PR reviews page into a
Google-Docs-style outline: the left sidebar is now a clean number+title
agenda with scroll-spy highlighting of the active block; each block shows
its title + description (sticky) above its diff; and diff rows are pinned to
a uniform height so scroll-to lands precisely via the virtualizer's own
geometry instead of an estimate-driven correction loop.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 0b76afdc955e33805c7623d1502a75a9c7c9c1b7)
* fix: jump + ResizeObserver settle for review scroll-to (#1655)
Replace smooth-scroll plus frame-count correction loops on the PR
reviews page with an instant jump that re-asserts its target via a
ResizeObserver (the real "layout settled" signal). Block/file
navigation and finding/comment centering now land deterministically as
off-screen cards mount, files expand, and annotation cards measure,
instead of racing a smooth-scroll animation against height
reconciliation. Holds bail on user wheel/touch input and after a short
ceiling, and a new navigation cancels the previous hold.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
(cherry picked from commit 7530653bba7774d66a54b8bef0d2bbc25f519942)
* fix: purge expired thread_wakeup crons (#1656)
* fix: purge expired thread_wakeup crons
One-shot wakeup crons set an end_time that stops re-firing but the cron
row is never deleted, so dead rows accumulate (86 in prod). Add a purge
that deletes thread_wakeup crons past their end_time, called
opportunistically before scheduling a new wakeup, plus a one-time
backfill script. Conservative: matches only kind=thread_wakeup with a
past end_time.
* chore: retrigger Open SWE review
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 9e5a1924ef306269322c31342a1831e57831cfee)
* fix: add top padding to sticky review block header (#1660)
* fix: add top padding to sticky review block header
The sticky per-block header on the reviews page had padding below but
none above, so the block number badge sat glued against the top edge
when pinned. Add matching top padding for breathing room.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* chore: use py-2 shorthand for review block header padding
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 23bd4a63fc5ba0fe853babf79ed33feb866cc8b2)
* fix: use global tokens for sidebar filter popover border (#1661)
The filter popover renders via base-ui Menu.Portal into document.body,
outside the .agents-ui container where the --ui-* CSS variables are
scoped. As a result border-[var(--ui-border)] resolved to an undefined
variable and border-color fell back to currentColor, producing a strong
near-black border (separators/hover/labels were similarly off).
Switch the portaled popup styling to the same global shadcn tokens the
theme/settings popover (SidebarUserMenu) already uses (border-border,
bg-border, bg-muted, text-muted-foreground). These are defined at :root
so they resolve inside portals too, and match the settings popover.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 63eb9a08209f683016abf01cdcc548bc5905f158)
* fix: preserve dashboard redirect after login (#1668)
* fix: preserve dashboard redirect after login
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: cover plan login redirect in e2e
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit bc7ce59169b5350da7286164afb83a7b037b528d)
* Disable React StrictMode (#1654)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 6575c327a3ac2b107a6e79a04fa61168d779dbf0)
* docs(upstream-sync): add cherry-pick runbook
Repo-specific runbook for bringing upstream (langchain-ai/open-swe) commits
into the fork: triage-sync discovery, the git cp workflow, the triage ledger,
themed-branch layout, and conflict/regression handling.
---------
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Ramon Nogueira <ramon.nogueira@langchain.dev>
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: Caroline di Vittorio <43390382+carolinedivittorio@users.noreply.github.com>
2026-07-03 11:48:40 -04:00
|
|
|
if (kind === "approve") {
|
|
|
|
|
await approvePlan(plan.threadId)
|
|
|
|
|
await navigate({
|
|
|
|
|
to: "/agents/$threadId",
|
|
|
|
|
params: { threadId: plan.threadId },
|
|
|
|
|
})
|
|
|
|
|
return
|
|
|
|
|
}
|
|
|
|
|
await rejectPlan(plan.threadId)
|
|
|
|
|
setDecision("Changes requested — the agent is revising the plan.")
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
} catch (e) {
|
|
|
|
|
setError((e as Error).message)
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
} finally {
|
|
|
|
|
setBusy(null)
|
|
|
|
|
}
|
|
|
|
|
},
|
chore: cherry-pick clean upstream fixes + cherry-pick runbook (#117)
* fix: make plan view mobile friendly (#1636)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 7ee3e0572406359632502b0d65450709a03645ea)
* fix: return to thread after plan approval (#1637)
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit f32e492ab46c120130e0c63eeca3eb353f10d83e)
* feat: reviews block agenda, sticky headers, accurate diff scroll (#1653)
Rework the AI-sorted blocks experience on the PR reviews page into a
Google-Docs-style outline: the left sidebar is now a clean number+title
agenda with scroll-spy highlighting of the active block; each block shows
its title + description (sticky) above its diff; and diff rows are pinned to
a uniform height so scroll-to lands precisely via the virtualizer's own
geometry instead of an estimate-driven correction loop.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 0b76afdc955e33805c7623d1502a75a9c7c9c1b7)
* fix: jump + ResizeObserver settle for review scroll-to (#1655)
Replace smooth-scroll plus frame-count correction loops on the PR
reviews page with an instant jump that re-asserts its target via a
ResizeObserver (the real "layout settled" signal). Block/file
navigation and finding/comment centering now land deterministically as
off-screen cards mount, files expand, and annotation cards measure,
instead of racing a smooth-scroll animation against height
reconciliation. Holds bail on user wheel/touch input and after a short
ceiling, and a new navigation cancels the previous hold.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
(cherry picked from commit 7530653bba7774d66a54b8bef0d2bbc25f519942)
* fix: purge expired thread_wakeup crons (#1656)
* fix: purge expired thread_wakeup crons
One-shot wakeup crons set an end_time that stops re-firing but the cron
row is never deleted, so dead rows accumulate (86 in prod). Add a purge
that deletes thread_wakeup crons past their end_time, called
opportunistically before scheduling a new wakeup, plus a one-time
backfill script. Conservative: matches only kind=thread_wakeup with a
past end_time.
* chore: retrigger Open SWE review
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 9e5a1924ef306269322c31342a1831e57831cfee)
* fix: add top padding to sticky review block header (#1660)
* fix: add top padding to sticky review block header
The sticky per-block header on the reviews page had padding below but
none above, so the block number badge sat glued against the top edge
when pinned. Add matching top padding for breathing room.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* chore: use py-2 shorthand for review block header padding
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 23bd4a63fc5ba0fe853babf79ed33feb866cc8b2)
* fix: use global tokens for sidebar filter popover border (#1661)
The filter popover renders via base-ui Menu.Portal into document.body,
outside the .agents-ui container where the --ui-* CSS variables are
scoped. As a result border-[var(--ui-border)] resolved to an undefined
variable and border-color fell back to currentColor, producing a strong
near-black border (separators/hover/labels were similarly off).
Switch the portaled popup styling to the same global shadcn tokens the
theme/settings popover (SidebarUserMenu) already uses (border-border,
bg-border, bg-muted, text-muted-foreground). These are defined at :root
so they resolve inside portals too, and match the settings popover.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 63eb9a08209f683016abf01cdcc548bc5905f158)
* fix: preserve dashboard redirect after login (#1668)
* fix: preserve dashboard redirect after login
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: cover plan login redirect in e2e
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit bc7ce59169b5350da7286164afb83a7b037b528d)
* Disable React StrictMode (#1654)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 6575c327a3ac2b107a6e79a04fa61168d779dbf0)
* docs(upstream-sync): add cherry-pick runbook
Repo-specific runbook for bringing upstream (langchain-ai/open-swe) commits
into the fork: triage-sync discovery, the git cp workflow, the triage ledger,
themed-branch layout, and conflict/regression handling.
---------
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Ramon Nogueira <ramon.nogueira@langchain.dev>
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: Caroline di Vittorio <43390382+carolinedivittorio@users.noreply.github.com>
2026-07-03 11:48:40 -04:00
|
|
|
[navigate, plan.threadId]
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
)
|
|
|
|
|
|
2026-06-24 15:07:25 -04:00
|
|
|
const copyPlan = useCallback(async () => {
|
|
|
|
|
setError(null)
|
feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80) (#130)
* feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80)
Adds a PUT /dashboard/api/plan/{thread_id} endpoint and PlanReview UI edit
mode so the thread owner can refine the published plan markdown by hand. The
edited markdown is re-published as "ready" (preserving reviewer comments),
mirrored into the sandbox plan.md, and handed to the agent as the source of
truth on approve.
Approve now reads the published plan content strictly (raise_on_error=True)
so a transient store failure aborts instead of silently dropping an edited
plan, matching the comment-read contract.
The banner-overlap fix (collapsed git-panel clearing the "Review plan" link)
was already ported in #128; this picks up the remaining edit-mode pieces.
Refs #80
* fix(plan): make approve_plan idempotent, dispatch before persisting, fix comment count
SH-128-03: approve_plan set status APPROVED before dispatching the follow-up
run and had no already-approved guard, so a failed dispatch left the plan stuck
approved-but-undispatched and a double-submit double-dispatched + double-posted
the Slack notice. And the Slack notice counted len(comments) including empty
comments _format_comments filters out.
- Return 409 when the plan is already approved (idempotent double-click/retry).
- Dispatch the implementation run BEFORE persisting APPROVED so a dispatch
failure leaves the plan re-approvable. _dispatch_followup passes plan_mode
explicitly, so the run is unaffected by the reorder.
- Count only non-empty comments in the Slack approval notice.
Fixed here (not on #128) because #128's approve_plan is rewritten on this
branch; #129 inherits it. Adds tests for the 409, the filtered count, and the
dispatch-before-status ordering.
---------
Co-authored-by: seahaven-openswe[bot] <296972425+seahaven-openswe[bot]@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-08 18:44:56 -04:00
|
|
|
if (await copyToClipboard(markdown)) {
|
2026-06-24 15:07:25 -04:00
|
|
|
setCopied(true)
|
|
|
|
|
window.setTimeout(() => setCopied(false), 1500)
|
|
|
|
|
} else {
|
|
|
|
|
setError("Couldn't copy the plan to the clipboard.")
|
|
|
|
|
}
|
feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80) (#130)
* feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80)
Adds a PUT /dashboard/api/plan/{thread_id} endpoint and PlanReview UI edit
mode so the thread owner can refine the published plan markdown by hand. The
edited markdown is re-published as "ready" (preserving reviewer comments),
mirrored into the sandbox plan.md, and handed to the agent as the source of
truth on approve.
Approve now reads the published plan content strictly (raise_on_error=True)
so a transient store failure aborts instead of silently dropping an edited
plan, matching the comment-read contract.
The banner-overlap fix (collapsed git-panel clearing the "Review plan" link)
was already ported in #128; this picks up the remaining edit-mode pieces.
Refs #80
* fix(plan): make approve_plan idempotent, dispatch before persisting, fix comment count
SH-128-03: approve_plan set status APPROVED before dispatching the follow-up
run and had no already-approved guard, so a failed dispatch left the plan stuck
approved-but-undispatched and a double-submit double-dispatched + double-posted
the Slack notice. And the Slack notice counted len(comments) including empty
comments _format_comments filters out.
- Return 409 when the plan is already approved (idempotent double-click/retry).
- Dispatch the implementation run BEFORE persisting APPROVED so a dispatch
failure leaves the plan re-approvable. _dispatch_followup passes plan_mode
explicitly, so the run is unaffected by the reorder.
- Count only non-empty comments in the Slack approval notice.
Fixed here (not on #128) because #128's approve_plan is rewritten on this
branch; #129 inherits it. Adds tests for the 409, the filtered count, and the
dispatch-before-status ordering.
---------
Co-authored-by: seahaven-openswe[bot] <296972425+seahaven-openswe[bot]@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-08 18:44:56 -04:00
|
|
|
}, [markdown])
|
2026-06-24 15:07:25 -04:00
|
|
|
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
return (
|
|
|
|
|
<div
|
|
|
|
|
data-testid="plan-review"
|
|
|
|
|
className="flex min-h-0 flex-1 flex-col bg-[var(--ui-bg)] text-[var(--ui-text)]"
|
|
|
|
|
>
|
chore: cherry-pick clean upstream fixes + cherry-pick runbook (#117)
* fix: make plan view mobile friendly (#1636)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 7ee3e0572406359632502b0d65450709a03645ea)
* fix: return to thread after plan approval (#1637)
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit f32e492ab46c120130e0c63eeca3eb353f10d83e)
* feat: reviews block agenda, sticky headers, accurate diff scroll (#1653)
Rework the AI-sorted blocks experience on the PR reviews page into a
Google-Docs-style outline: the left sidebar is now a clean number+title
agenda with scroll-spy highlighting of the active block; each block shows
its title + description (sticky) above its diff; and diff rows are pinned to
a uniform height so scroll-to lands precisely via the virtualizer's own
geometry instead of an estimate-driven correction loop.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 0b76afdc955e33805c7623d1502a75a9c7c9c1b7)
* fix: jump + ResizeObserver settle for review scroll-to (#1655)
Replace smooth-scroll plus frame-count correction loops on the PR
reviews page with an instant jump that re-asserts its target via a
ResizeObserver (the real "layout settled" signal). Block/file
navigation and finding/comment centering now land deterministically as
off-screen cards mount, files expand, and annotation cards measure,
instead of racing a smooth-scroll animation against height
reconciliation. Holds bail on user wheel/touch input and after a short
ceiling, and a new navigation cancels the previous hold.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
(cherry picked from commit 7530653bba7774d66a54b8bef0d2bbc25f519942)
* fix: purge expired thread_wakeup crons (#1656)
* fix: purge expired thread_wakeup crons
One-shot wakeup crons set an end_time that stops re-firing but the cron
row is never deleted, so dead rows accumulate (86 in prod). Add a purge
that deletes thread_wakeup crons past their end_time, called
opportunistically before scheduling a new wakeup, plus a one-time
backfill script. Conservative: matches only kind=thread_wakeup with a
past end_time.
* chore: retrigger Open SWE review
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 9e5a1924ef306269322c31342a1831e57831cfee)
* fix: add top padding to sticky review block header (#1660)
* fix: add top padding to sticky review block header
The sticky per-block header on the reviews page had padding below but
none above, so the block number badge sat glued against the top edge
when pinned. Add matching top padding for breathing room.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* chore: use py-2 shorthand for review block header padding
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 23bd4a63fc5ba0fe853babf79ed33feb866cc8b2)
* fix: use global tokens for sidebar filter popover border (#1661)
The filter popover renders via base-ui Menu.Portal into document.body,
outside the .agents-ui container where the --ui-* CSS variables are
scoped. As a result border-[var(--ui-border)] resolved to an undefined
variable and border-color fell back to currentColor, producing a strong
near-black border (separators/hover/labels were similarly off).
Switch the portaled popup styling to the same global shadcn tokens the
theme/settings popover (SidebarUserMenu) already uses (border-border,
bg-border, bg-muted, text-muted-foreground). These are defined at :root
so they resolve inside portals too, and match the settings popover.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 63eb9a08209f683016abf01cdcc548bc5905f158)
* fix: preserve dashboard redirect after login (#1668)
* fix: preserve dashboard redirect after login
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: cover plan login redirect in e2e
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit bc7ce59169b5350da7286164afb83a7b037b528d)
* Disable React StrictMode (#1654)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 6575c327a3ac2b107a6e79a04fa61168d779dbf0)
* docs(upstream-sync): add cherry-pick runbook
Repo-specific runbook for bringing upstream (langchain-ai/open-swe) commits
into the fork: triage-sync discovery, the git cp workflow, the triage ledger,
themed-branch layout, and conflict/regression handling.
---------
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Ramon Nogueira <ramon.nogueira@langchain.dev>
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: Caroline di Vittorio <43390382+carolinedivittorio@users.noreply.github.com>
2026-07-03 11:48:40 -04:00
|
|
|
<div className="flex flex-col gap-3 border-b border-[var(--ui-border)] px-4 py-3 md:flex-row md:items-center md:justify-between md:gap-4 md:px-6">
|
|
|
|
|
<div className="min-w-0">
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
<h1 className="text-base font-semibold text-[var(--ui-text)]">
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
{isShared ? "Shared response" : "Implementation plan"}
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
</h1>
|
|
|
|
|
<p className="text-xs text-[var(--ui-text-dim)]">
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
{isShared ? "Viewing" : "Reviewing"} as {plan.user.name}
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
{plan.isOwner ? " (owner)" : ""} · status:{" "}
|
|
|
|
|
<span data-testid="plan-status">{plan.status}</span>
|
|
|
|
|
</p>
|
|
|
|
|
</div>
|
chore: cherry-pick clean upstream fixes + cherry-pick runbook (#117)
* fix: make plan view mobile friendly (#1636)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 7ee3e0572406359632502b0d65450709a03645ea)
* fix: return to thread after plan approval (#1637)
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit f32e492ab46c120130e0c63eeca3eb353f10d83e)
* feat: reviews block agenda, sticky headers, accurate diff scroll (#1653)
Rework the AI-sorted blocks experience on the PR reviews page into a
Google-Docs-style outline: the left sidebar is now a clean number+title
agenda with scroll-spy highlighting of the active block; each block shows
its title + description (sticky) above its diff; and diff rows are pinned to
a uniform height so scroll-to lands precisely via the virtualizer's own
geometry instead of an estimate-driven correction loop.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 0b76afdc955e33805c7623d1502a75a9c7c9c1b7)
* fix: jump + ResizeObserver settle for review scroll-to (#1655)
Replace smooth-scroll plus frame-count correction loops on the PR
reviews page with an instant jump that re-asserts its target via a
ResizeObserver (the real "layout settled" signal). Block/file
navigation and finding/comment centering now land deterministically as
off-screen cards mount, files expand, and annotation cards measure,
instead of racing a smooth-scroll animation against height
reconciliation. Holds bail on user wheel/touch input and after a short
ceiling, and a new navigation cancels the previous hold.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
(cherry picked from commit 7530653bba7774d66a54b8bef0d2bbc25f519942)
* fix: purge expired thread_wakeup crons (#1656)
* fix: purge expired thread_wakeup crons
One-shot wakeup crons set an end_time that stops re-firing but the cron
row is never deleted, so dead rows accumulate (86 in prod). Add a purge
that deletes thread_wakeup crons past their end_time, called
opportunistically before scheduling a new wakeup, plus a one-time
backfill script. Conservative: matches only kind=thread_wakeup with a
past end_time.
* chore: retrigger Open SWE review
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 9e5a1924ef306269322c31342a1831e57831cfee)
* fix: add top padding to sticky review block header (#1660)
* fix: add top padding to sticky review block header
The sticky per-block header on the reviews page had padding below but
none above, so the block number badge sat glued against the top edge
when pinned. Add matching top padding for breathing room.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* chore: use py-2 shorthand for review block header padding
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 23bd4a63fc5ba0fe853babf79ed33feb866cc8b2)
* fix: use global tokens for sidebar filter popover border (#1661)
The filter popover renders via base-ui Menu.Portal into document.body,
outside the .agents-ui container where the --ui-* CSS variables are
scoped. As a result border-[var(--ui-border)] resolved to an undefined
variable and border-color fell back to currentColor, producing a strong
near-black border (separators/hover/labels were similarly off).
Switch the portaled popup styling to the same global shadcn tokens the
theme/settings popover (SidebarUserMenu) already uses (border-border,
bg-border, bg-muted, text-muted-foreground). These are defined at :root
so they resolve inside portals too, and match the settings popover.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 63eb9a08209f683016abf01cdcc548bc5905f158)
* fix: preserve dashboard redirect after login (#1668)
* fix: preserve dashboard redirect after login
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: cover plan login redirect in e2e
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit bc7ce59169b5350da7286164afb83a7b037b528d)
* Disable React StrictMode (#1654)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 6575c327a3ac2b107a6e79a04fa61168d779dbf0)
* docs(upstream-sync): add cherry-pick runbook
Repo-specific runbook for bringing upstream (langchain-ai/open-swe) commits
into the fork: triage-sync discovery, the git cp workflow, the triage ledger,
themed-branch layout, and conflict/regression handling.
---------
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Ramon Nogueira <ramon.nogueira@langchain.dev>
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: Caroline di Vittorio <43390382+carolinedivittorio@users.noreply.github.com>
2026-07-03 11:48:40 -04:00
|
|
|
<div className="flex min-w-0 flex-wrap items-center gap-2 md:shrink-0 md:justify-end">
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
{decision && (
|
|
|
|
|
<span
|
|
|
|
|
data-testid="plan-decision"
|
chore: cherry-pick clean upstream fixes + cherry-pick runbook (#117)
* fix: make plan view mobile friendly (#1636)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 7ee3e0572406359632502b0d65450709a03645ea)
* fix: return to thread after plan approval (#1637)
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit f32e492ab46c120130e0c63eeca3eb353f10d83e)
* feat: reviews block agenda, sticky headers, accurate diff scroll (#1653)
Rework the AI-sorted blocks experience on the PR reviews page into a
Google-Docs-style outline: the left sidebar is now a clean number+title
agenda with scroll-spy highlighting of the active block; each block shows
its title + description (sticky) above its diff; and diff rows are pinned to
a uniform height so scroll-to lands precisely via the virtualizer's own
geometry instead of an estimate-driven correction loop.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 0b76afdc955e33805c7623d1502a75a9c7c9c1b7)
* fix: jump + ResizeObserver settle for review scroll-to (#1655)
Replace smooth-scroll plus frame-count correction loops on the PR
reviews page with an instant jump that re-asserts its target via a
ResizeObserver (the real "layout settled" signal). Block/file
navigation and finding/comment centering now land deterministically as
off-screen cards mount, files expand, and annotation cards measure,
instead of racing a smooth-scroll animation against height
reconciliation. Holds bail on user wheel/touch input and after a short
ceiling, and a new navigation cancels the previous hold.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
(cherry picked from commit 7530653bba7774d66a54b8bef0d2bbc25f519942)
* fix: purge expired thread_wakeup crons (#1656)
* fix: purge expired thread_wakeup crons
One-shot wakeup crons set an end_time that stops re-firing but the cron
row is never deleted, so dead rows accumulate (86 in prod). Add a purge
that deletes thread_wakeup crons past their end_time, called
opportunistically before scheduling a new wakeup, plus a one-time
backfill script. Conservative: matches only kind=thread_wakeup with a
past end_time.
* chore: retrigger Open SWE review
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 9e5a1924ef306269322c31342a1831e57831cfee)
* fix: add top padding to sticky review block header (#1660)
* fix: add top padding to sticky review block header
The sticky per-block header on the reviews page had padding below but
none above, so the block number badge sat glued against the top edge
when pinned. Add matching top padding for breathing room.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* chore: use py-2 shorthand for review block header padding
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 23bd4a63fc5ba0fe853babf79ed33feb866cc8b2)
* fix: use global tokens for sidebar filter popover border (#1661)
The filter popover renders via base-ui Menu.Portal into document.body,
outside the .agents-ui container where the --ui-* CSS variables are
scoped. As a result border-[var(--ui-border)] resolved to an undefined
variable and border-color fell back to currentColor, producing a strong
near-black border (separators/hover/labels were similarly off).
Switch the portaled popup styling to the same global shadcn tokens the
theme/settings popover (SidebarUserMenu) already uses (border-border,
bg-border, bg-muted, text-muted-foreground). These are defined at :root
so they resolve inside portals too, and match the settings popover.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 63eb9a08209f683016abf01cdcc548bc5905f158)
* fix: preserve dashboard redirect after login (#1668)
* fix: preserve dashboard redirect after login
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: cover plan login redirect in e2e
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit bc7ce59169b5350da7286164afb83a7b037b528d)
* Disable React StrictMode (#1654)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 6575c327a3ac2b107a6e79a04fa61168d779dbf0)
* docs(upstream-sync): add cherry-pick runbook
Repo-specific runbook for bringing upstream (langchain-ai/open-swe) commits
into the fork: triage-sync discovery, the git cp workflow, the triage ledger,
themed-branch layout, and conflict/regression handling.
---------
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Ramon Nogueira <ramon.nogueira@langchain.dev>
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: Caroline di Vittorio <43390382+carolinedivittorio@users.noreply.github.com>
2026-07-03 11:48:40 -04:00
|
|
|
className="w-full text-xs text-[var(--ui-text-dim)] md:w-auto"
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
>
|
|
|
|
|
{decision}
|
|
|
|
|
</span>
|
|
|
|
|
)}
|
2026-06-24 15:07:25 -04:00
|
|
|
<Button
|
|
|
|
|
data-testid="copy-plan"
|
|
|
|
|
variant="secondary"
|
feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80) (#130)
* feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80)
Adds a PUT /dashboard/api/plan/{thread_id} endpoint and PlanReview UI edit
mode so the thread owner can refine the published plan markdown by hand. The
edited markdown is re-published as "ready" (preserving reviewer comments),
mirrored into the sandbox plan.md, and handed to the agent as the source of
truth on approve.
Approve now reads the published plan content strictly (raise_on_error=True)
so a transient store failure aborts instead of silently dropping an edited
plan, matching the comment-read contract.
The banner-overlap fix (collapsed git-panel clearing the "Review plan" link)
was already ported in #128; this picks up the remaining edit-mode pieces.
Refs #80
* fix(plan): make approve_plan idempotent, dispatch before persisting, fix comment count
SH-128-03: approve_plan set status APPROVED before dispatching the follow-up
run and had no already-approved guard, so a failed dispatch left the plan stuck
approved-but-undispatched and a double-submit double-dispatched + double-posted
the Slack notice. And the Slack notice counted len(comments) including empty
comments _format_comments filters out.
- Return 409 when the plan is already approved (idempotent double-click/retry).
- Dispatch the implementation run BEFORE persisting APPROVED so a dispatch
failure leaves the plan re-approvable. _dispatch_followup passes plan_mode
explicitly, so the run is unaffected by the reorder.
- Count only non-empty comments in the Slack approval notice.
Fixed here (not on #128) because #128's approve_plan is rewritten on this
branch; #129 inherits it. Adds tests for the 409, the filtered count, and the
dispatch-before-status ordering.
---------
Co-authored-by: seahaven-openswe[bot] <296972425+seahaven-openswe[bot]@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-08 18:44:56 -04:00
|
|
|
disabled={!markdown.trim()}
|
2026-06-24 15:07:25 -04:00
|
|
|
onClick={() => void copyPlan()}
|
|
|
|
|
>
|
|
|
|
|
{copied ? "Copied!" : "Copy markdown"}
|
|
|
|
|
</Button>
|
feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80) (#130)
* feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80)
Adds a PUT /dashboard/api/plan/{thread_id} endpoint and PlanReview UI edit
mode so the thread owner can refine the published plan markdown by hand. The
edited markdown is re-published as "ready" (preserving reviewer comments),
mirrored into the sandbox plan.md, and handed to the agent as the source of
truth on approve.
Approve now reads the published plan content strictly (raise_on_error=True)
so a transient store failure aborts instead of silently dropping an edited
plan, matching the comment-read contract.
The banner-overlap fix (collapsed git-panel clearing the "Review plan" link)
was already ported in #128; this picks up the remaining edit-mode pieces.
Refs #80
* fix(plan): make approve_plan idempotent, dispatch before persisting, fix comment count
SH-128-03: approve_plan set status APPROVED before dispatching the follow-up
run and had no already-approved guard, so a failed dispatch left the plan stuck
approved-but-undispatched and a double-submit double-dispatched + double-posted
the Slack notice. And the Slack notice counted len(comments) including empty
comments _format_comments filters out.
- Return 409 when the plan is already approved (idempotent double-click/retry).
- Dispatch the implementation run BEFORE persisting APPROVED so a dispatch
failure leaves the plan re-approvable. _dispatch_followup passes plan_mode
explicitly, so the run is unaffected by the reorder.
- Count only non-empty comments in the Slack approval notice.
Fixed here (not on #128) because #128's approve_plan is rewritten on this
branch; #129 inherits it. Adds tests for the 409, the filtered count, and the
dispatch-before-status ordering.
---------
Co-authored-by: seahaven-openswe[bot] <296972425+seahaven-openswe[bot]@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-08 18:44:56 -04:00
|
|
|
{canEdit && (
|
|
|
|
|
<Button
|
|
|
|
|
data-testid="edit-plan"
|
|
|
|
|
variant="secondary"
|
|
|
|
|
disabled={busy !== null || decision !== null}
|
|
|
|
|
onClick={startEditing}
|
|
|
|
|
>
|
|
|
|
|
Edit
|
|
|
|
|
</Button>
|
|
|
|
|
)}
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
{!isShared && plan.isOwner && (
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
<Button
|
|
|
|
|
data-testid="approve-plan"
|
|
|
|
|
disabled={busy !== null || decision !== null}
|
|
|
|
|
onClick={() => void decide("approve")}
|
|
|
|
|
>
|
|
|
|
|
Approve
|
|
|
|
|
</Button>
|
|
|
|
|
)}
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
{!isShared && (
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
<Button
|
|
|
|
|
data-testid="reject-plan"
|
|
|
|
|
variant="secondary"
|
2026-06-23 19:02:08 -04:00
|
|
|
// Requesting changes feeds the comments to the agent, so it's
|
|
|
|
|
// meaningless with none — disable until at least one is left.
|
|
|
|
|
disabled={busy !== null || decision !== null || comments.length === 0}
|
|
|
|
|
title={
|
|
|
|
|
comments.length === 0
|
|
|
|
|
? "Leave a comment first to request changes"
|
|
|
|
|
: undefined
|
|
|
|
|
}
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
onClick={() => void decide("reject")}
|
|
|
|
|
>
|
|
|
|
|
Request changes
|
|
|
|
|
</Button>
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
)}
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
</div>
|
|
|
|
|
</div>
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
|
chore: cherry-pick clean upstream fixes + cherry-pick runbook (#117)
* fix: make plan view mobile friendly (#1636)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 7ee3e0572406359632502b0d65450709a03645ea)
* fix: return to thread after plan approval (#1637)
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit f32e492ab46c120130e0c63eeca3eb353f10d83e)
* feat: reviews block agenda, sticky headers, accurate diff scroll (#1653)
Rework the AI-sorted blocks experience on the PR reviews page into a
Google-Docs-style outline: the left sidebar is now a clean number+title
agenda with scroll-spy highlighting of the active block; each block shows
its title + description (sticky) above its diff; and diff rows are pinned to
a uniform height so scroll-to lands precisely via the virtualizer's own
geometry instead of an estimate-driven correction loop.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 0b76afdc955e33805c7623d1502a75a9c7c9c1b7)
* fix: jump + ResizeObserver settle for review scroll-to (#1655)
Replace smooth-scroll plus frame-count correction loops on the PR
reviews page with an instant jump that re-asserts its target via a
ResizeObserver (the real "layout settled" signal). Block/file
navigation and finding/comment centering now land deterministically as
off-screen cards mount, files expand, and annotation cards measure,
instead of racing a smooth-scroll animation against height
reconciliation. Holds bail on user wheel/touch input and after a short
ceiling, and a new navigation cancels the previous hold.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
(cherry picked from commit 7530653bba7774d66a54b8bef0d2bbc25f519942)
* fix: purge expired thread_wakeup crons (#1656)
* fix: purge expired thread_wakeup crons
One-shot wakeup crons set an end_time that stops re-firing but the cron
row is never deleted, so dead rows accumulate (86 in prod). Add a purge
that deletes thread_wakeup crons past their end_time, called
opportunistically before scheduling a new wakeup, plus a one-time
backfill script. Conservative: matches only kind=thread_wakeup with a
past end_time.
* chore: retrigger Open SWE review
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 9e5a1924ef306269322c31342a1831e57831cfee)
* fix: add top padding to sticky review block header (#1660)
* fix: add top padding to sticky review block header
The sticky per-block header on the reviews page had padding below but
none above, so the block number badge sat glued against the top edge
when pinned. Add matching top padding for breathing room.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* chore: use py-2 shorthand for review block header padding
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 23bd4a63fc5ba0fe853babf79ed33feb866cc8b2)
* fix: use global tokens for sidebar filter popover border (#1661)
The filter popover renders via base-ui Menu.Portal into document.body,
outside the .agents-ui container where the --ui-* CSS variables are
scoped. As a result border-[var(--ui-border)] resolved to an undefined
variable and border-color fell back to currentColor, producing a strong
near-black border (separators/hover/labels were similarly off).
Switch the portaled popup styling to the same global shadcn tokens the
theme/settings popover (SidebarUserMenu) already uses (border-border,
bg-border, bg-muted, text-muted-foreground). These are defined at :root
so they resolve inside portals too, and match the settings popover.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 63eb9a08209f683016abf01cdcc548bc5905f158)
* fix: preserve dashboard redirect after login (#1668)
* fix: preserve dashboard redirect after login
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: cover plan login redirect in e2e
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit bc7ce59169b5350da7286164afb83a7b037b528d)
* Disable React StrictMode (#1654)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 6575c327a3ac2b107a6e79a04fa61168d779dbf0)
* docs(upstream-sync): add cherry-pick runbook
Repo-specific runbook for bringing upstream (langchain-ai/open-swe) commits
into the fork: triage-sync discovery, the git cp workflow, the triage ledger,
themed-branch layout, and conflict/regression handling.
---------
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Ramon Nogueira <ramon.nogueira@langchain.dev>
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: Caroline di Vittorio <43390382+carolinedivittorio@users.noreply.github.com>
2026-07-03 11:48:40 -04:00
|
|
|
<div className="flex min-h-0 flex-1 flex-col overflow-y-auto md:flex-row md:overflow-hidden">
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
<div
|
chore: cherry-pick clean upstream fixes + cherry-pick runbook (#117)
* fix: make plan view mobile friendly (#1636)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 7ee3e0572406359632502b0d65450709a03645ea)
* fix: return to thread after plan approval (#1637)
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit f32e492ab46c120130e0c63eeca3eb353f10d83e)
* feat: reviews block agenda, sticky headers, accurate diff scroll (#1653)
Rework the AI-sorted blocks experience on the PR reviews page into a
Google-Docs-style outline: the left sidebar is now a clean number+title
agenda with scroll-spy highlighting of the active block; each block shows
its title + description (sticky) above its diff; and diff rows are pinned to
a uniform height so scroll-to lands precisely via the virtualizer's own
geometry instead of an estimate-driven correction loop.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 0b76afdc955e33805c7623d1502a75a9c7c9c1b7)
* fix: jump + ResizeObserver settle for review scroll-to (#1655)
Replace smooth-scroll plus frame-count correction loops on the PR
reviews page with an instant jump that re-asserts its target via a
ResizeObserver (the real "layout settled" signal). Block/file
navigation and finding/comment centering now land deterministically as
off-screen cards mount, files expand, and annotation cards measure,
instead of racing a smooth-scroll animation against height
reconciliation. Holds bail on user wheel/touch input and after a short
ceiling, and a new navigation cancels the previous hold.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
(cherry picked from commit 7530653bba7774d66a54b8bef0d2bbc25f519942)
* fix: purge expired thread_wakeup crons (#1656)
* fix: purge expired thread_wakeup crons
One-shot wakeup crons set an end_time that stops re-firing but the cron
row is never deleted, so dead rows accumulate (86 in prod). Add a purge
that deletes thread_wakeup crons past their end_time, called
opportunistically before scheduling a new wakeup, plus a one-time
backfill script. Conservative: matches only kind=thread_wakeup with a
past end_time.
* chore: retrigger Open SWE review
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 9e5a1924ef306269322c31342a1831e57831cfee)
* fix: add top padding to sticky review block header (#1660)
* fix: add top padding to sticky review block header
The sticky per-block header on the reviews page had padding below but
none above, so the block number badge sat glued against the top edge
when pinned. Add matching top padding for breathing room.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* chore: use py-2 shorthand for review block header padding
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 23bd4a63fc5ba0fe853babf79ed33feb866cc8b2)
* fix: use global tokens for sidebar filter popover border (#1661)
The filter popover renders via base-ui Menu.Portal into document.body,
outside the .agents-ui container where the --ui-* CSS variables are
scoped. As a result border-[var(--ui-border)] resolved to an undefined
variable and border-color fell back to currentColor, producing a strong
near-black border (separators/hover/labels were similarly off).
Switch the portaled popup styling to the same global shadcn tokens the
theme/settings popover (SidebarUserMenu) already uses (border-border,
bg-border, bg-muted, text-muted-foreground). These are defined at :root
so they resolve inside portals too, and match the settings popover.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 63eb9a08209f683016abf01cdcc548bc5905f158)
* fix: preserve dashboard redirect after login (#1668)
* fix: preserve dashboard redirect after login
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: cover plan login redirect in e2e
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit bc7ce59169b5350da7286164afb83a7b037b528d)
* Disable React StrictMode (#1654)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 6575c327a3ac2b107a6e79a04fa61168d779dbf0)
* docs(upstream-sync): add cherry-pick runbook
Repo-specific runbook for bringing upstream (langchain-ai/open-swe) commits
into the fork: triage-sync discovery, the git cp workflow, the triage ledger,
themed-branch layout, and conflict/regression handling.
---------
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Ramon Nogueira <ramon.nogueira@langchain.dev>
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: Caroline di Vittorio <43390382+carolinedivittorio@users.noreply.github.com>
2026-07-03 11:48:40 -04:00
|
|
|
className="min-w-0 px-4 py-4 md:min-h-0 md:flex-1 md:overflow-auto md:px-6"
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
data-testid="plan-document"
|
|
|
|
|
data-color-scheme={resolvedTheme}
|
|
|
|
|
>
|
feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80) (#130)
* feat: editable plan mode — owner hand-edits the plan before approval (#1610, #80)
Adds a PUT /dashboard/api/plan/{thread_id} endpoint and PlanReview UI edit
mode so the thread owner can refine the published plan markdown by hand. The
edited markdown is re-published as "ready" (preserving reviewer comments),
mirrored into the sandbox plan.md, and handed to the agent as the source of
truth on approve.
Approve now reads the published plan content strictly (raise_on_error=True)
so a transient store failure aborts instead of silently dropping an edited
plan, matching the comment-read contract.
The banner-overlap fix (collapsed git-panel clearing the "Review plan" link)
was already ported in #128; this picks up the remaining edit-mode pieces.
Refs #80
* fix(plan): make approve_plan idempotent, dispatch before persisting, fix comment count
SH-128-03: approve_plan set status APPROVED before dispatching the follow-up
run and had no already-approved guard, so a failed dispatch left the plan stuck
approved-but-undispatched and a double-submit double-dispatched + double-posted
the Slack notice. And the Slack notice counted len(comments) including empty
comments _format_comments filters out.
- Return 409 when the plan is already approved (idempotent double-click/retry).
- Dispatch the implementation run BEFORE persisting APPROVED so a dispatch
failure leaves the plan re-approvable. _dispatch_followup passes plan_mode
explicitly, so the run is unaffected by the reorder.
- Count only non-empty comments in the Slack approval notice.
Fixed here (not on #128) because #128's approve_plan is rewritten on this
branch; #129 inherits it. Adds tests for the 409, the filtered count, and the
dispatch-before-status ordering.
---------
Co-authored-by: seahaven-openswe[bot] <296972425+seahaven-openswe[bot]@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-08 18:44:56 -04:00
|
|
|
{editing ? (
|
|
|
|
|
<div className="flex h-full flex-col gap-3">
|
|
|
|
|
<textarea
|
|
|
|
|
data-testid="plan-edit-textarea"
|
|
|
|
|
value={editDraft}
|
|
|
|
|
onChange={(e) => setEditDraft(e.target.value)}
|
|
|
|
|
className="min-h-0 flex-1 resize-none rounded-md border border-[var(--ui-border)] bg-[var(--ui-bg)] p-3 font-mono text-sm text-[var(--ui-text)] outline-none focus:border-[var(--ui-accent)]"
|
|
|
|
|
placeholder="Write the plan in Markdown…"
|
|
|
|
|
/>
|
|
|
|
|
<div className="flex shrink-0 justify-end gap-2">
|
|
|
|
|
<Button
|
|
|
|
|
data-testid="plan-edit-cancel"
|
|
|
|
|
variant="secondary"
|
|
|
|
|
disabled={saving}
|
|
|
|
|
onClick={cancelEditing}
|
|
|
|
|
>
|
|
|
|
|
Cancel
|
|
|
|
|
</Button>
|
|
|
|
|
<Button
|
|
|
|
|
data-testid="plan-edit-save"
|
|
|
|
|
disabled={saving || !editDraft.trim()}
|
|
|
|
|
onClick={() => void saveEdit()}
|
|
|
|
|
>
|
|
|
|
|
{saving ? "Saving…" : "Save"}
|
|
|
|
|
</Button>
|
|
|
|
|
</div>
|
|
|
|
|
</div>
|
|
|
|
|
) : markdown.trim() ? (
|
|
|
|
|
<Markdown content={markdown} />
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
) : (
|
|
|
|
|
<p className="text-sm text-[var(--ui-text-dim)]">
|
|
|
|
|
The plan hasn't been written yet.
|
|
|
|
|
</p>
|
|
|
|
|
)}
|
|
|
|
|
</div>
|
|
|
|
|
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
{!isShared && (<aside className="flex shrink-0 flex-col border-t border-[var(--ui-border)] md:w-80 md:border-t-0 md:border-l">
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
<div className="border-b border-[var(--ui-border)] px-4 py-3">
|
|
|
|
|
<h2 className="text-sm font-semibold text-[var(--ui-text)]">
|
|
|
|
|
Comments
|
|
|
|
|
</h2>
|
|
|
|
|
</div>
|
|
|
|
|
<div
|
chore: cherry-pick clean upstream fixes + cherry-pick runbook (#117)
* fix: make plan view mobile friendly (#1636)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 7ee3e0572406359632502b0d65450709a03645ea)
* fix: return to thread after plan approval (#1637)
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit f32e492ab46c120130e0c63eeca3eb353f10d83e)
* feat: reviews block agenda, sticky headers, accurate diff scroll (#1653)
Rework the AI-sorted blocks experience on the PR reviews page into a
Google-Docs-style outline: the left sidebar is now a clean number+title
agenda with scroll-spy highlighting of the active block; each block shows
its title + description (sticky) above its diff; and diff rows are pinned to
a uniform height so scroll-to lands precisely via the virtualizer's own
geometry instead of an estimate-driven correction loop.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 0b76afdc955e33805c7623d1502a75a9c7c9c1b7)
* fix: jump + ResizeObserver settle for review scroll-to (#1655)
Replace smooth-scroll plus frame-count correction loops on the PR
reviews page with an instant jump that re-asserts its target via a
ResizeObserver (the real "layout settled" signal). Block/file
navigation and finding/comment centering now land deterministically as
off-screen cards mount, files expand, and annotation cards measure,
instead of racing a smooth-scroll animation against height
reconciliation. Holds bail on user wheel/touch input and after a short
ceiling, and a new navigation cancels the previous hold.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
(cherry picked from commit 7530653bba7774d66a54b8bef0d2bbc25f519942)
* fix: purge expired thread_wakeup crons (#1656)
* fix: purge expired thread_wakeup crons
One-shot wakeup crons set an end_time that stops re-firing but the cron
row is never deleted, so dead rows accumulate (86 in prod). Add a purge
that deletes thread_wakeup crons past their end_time, called
opportunistically before scheduling a new wakeup, plus a one-time
backfill script. Conservative: matches only kind=thread_wakeup with a
past end_time.
* chore: retrigger Open SWE review
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 9e5a1924ef306269322c31342a1831e57831cfee)
* fix: add top padding to sticky review block header (#1660)
* fix: add top padding to sticky review block header
The sticky per-block header on the reviews page had padding below but
none above, so the block number badge sat glued against the top edge
when pinned. Add matching top padding for breathing room.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* chore: use py-2 shorthand for review block header padding
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 23bd4a63fc5ba0fe853babf79ed33feb866cc8b2)
* fix: use global tokens for sidebar filter popover border (#1661)
The filter popover renders via base-ui Menu.Portal into document.body,
outside the .agents-ui container where the --ui-* CSS variables are
scoped. As a result border-[var(--ui-border)] resolved to an undefined
variable and border-color fell back to currentColor, producing a strong
near-black border (separators/hover/labels were similarly off).
Switch the portaled popup styling to the same global shadcn tokens the
theme/settings popover (SidebarUserMenu) already uses (border-border,
bg-border, bg-muted, text-muted-foreground). These are defined at :root
so they resolve inside portals too, and match the settings popover.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 63eb9a08209f683016abf01cdcc548bc5905f158)
* fix: preserve dashboard redirect after login (#1668)
* fix: preserve dashboard redirect after login
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: cover plan login redirect in e2e
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
---------
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit bc7ce59169b5350da7286164afb83a7b037b528d)
* Disable React StrictMode (#1654)
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
(cherry picked from commit 6575c327a3ac2b107a6e79a04fa61168d779dbf0)
* docs(upstream-sync): add cherry-pick runbook
Repo-specific runbook for bringing upstream (langchain-ai/open-swe) commits
into the fork: triage-sync discovery, the git cp workflow, the triage ledger,
themed-branch layout, and conflict/regression handling.
---------
Co-authored-by: Johannes du Plessis <johannes@langchain.dev>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
Co-authored-by: Ramon Nogueira <ramon.nogueira@langchain.dev>
Co-authored-by: Ramon Nogueira <270434257+ramon-langchain@users.noreply.github.com>
Co-authored-by: Caroline di Vittorio <43390382+carolinedivittorio@users.noreply.github.com>
2026-07-03 11:48:40 -04:00
|
|
|
className="max-h-80 space-y-3 overflow-auto px-4 py-3 md:max-h-none md:min-h-0 md:flex-1"
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
data-testid="plan-comments"
|
|
|
|
|
>
|
|
|
|
|
{comments.length === 0 ? (
|
|
|
|
|
<p className="text-xs text-[var(--ui-text-dim)]">
|
|
|
|
|
No comments yet.
|
|
|
|
|
</p>
|
|
|
|
|
) : (
|
|
|
|
|
comments.map((c) => (
|
|
|
|
|
<div
|
|
|
|
|
key={c.id}
|
|
|
|
|
data-testid="plan-comment"
|
|
|
|
|
className="rounded-md border border-[var(--ui-border)] bg-[var(--ui-panel)] px-3 py-2"
|
|
|
|
|
>
|
|
|
|
|
<div className="flex items-center justify-between gap-2">
|
|
|
|
|
<span className="text-xs font-medium text-[var(--ui-text)]">
|
|
|
|
|
{c.author}
|
|
|
|
|
</span>
|
|
|
|
|
<button
|
|
|
|
|
type="button"
|
|
|
|
|
data-testid="comment-delete"
|
|
|
|
|
className="text-xs text-[var(--ui-text-dim)] hover:text-[var(--ui-text)]"
|
|
|
|
|
onClick={() => void removeComment(c.id)}
|
|
|
|
|
>
|
|
|
|
|
Delete
|
|
|
|
|
</button>
|
|
|
|
|
</div>
|
|
|
|
|
<p className="mt-1 text-sm whitespace-pre-wrap text-[var(--ui-text)]">
|
|
|
|
|
{c.body}
|
|
|
|
|
</p>
|
|
|
|
|
</div>
|
|
|
|
|
))
|
|
|
|
|
)}
|
|
|
|
|
</div>
|
|
|
|
|
<div className="border-t border-[var(--ui-border)] p-3">
|
|
|
|
|
{error && (
|
|
|
|
|
<p className="mb-2 text-xs text-[color:var(--ui-danger)]">
|
|
|
|
|
{error}
|
|
|
|
|
</p>
|
|
|
|
|
)}
|
|
|
|
|
<textarea
|
|
|
|
|
data-testid="comment-input"
|
|
|
|
|
value={draft}
|
|
|
|
|
onChange={(e) => setDraft(e.target.value)}
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
onKeyDown={handleCommentKeyDown}
|
refactor(open-swe): plain HTTP comments instead of Yjs/BlockNote collab (#1601)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
* refactor(plan-mode): replace Yjs/BlockNote collab with plain HTTP comments
Drop the realtime collaborative editor (it can't work behind Vercel's
rewrite — WebSocket upgrades aren't proxied to the external LangGraph
backend) in favor of a simple whole-document comments API over plain HTTP.
Backend:
- Remove the Yjs WebSocket server (plan_collab.py), its lifespan, and the
collab router; drop pycrdt / pycrdt-websocket deps.
- plan_store: replace the Yjs snapshot with comment CRUD (one store item per
comment under ["plan","comments",thread_id]).
- plan_api: add GET/POST/DELETE comment endpoints; approve/reject now read
comments server-side and format them for the follow-up run (no longer
client-harvested). Comment delete is author-or-owner; approve stays owner-only.
Frontend:
- PlanReview renders the plan markdown read-only and shows a comments panel
(list + add, polled every 4s for cross-user visibility).
- Drop @blocknote/*, y-websocket, yjs; lib/plan exposes get/add/deletePlanComment.
Tests: unit tests for the comments API + route registration; e2e drives the
HTTP comment UI (owner + collaborator, cross-user visibility, owner-only approve,
PR echoes the harvested feedback).
* fix(open-swe): clear stale plan comments on republish; fail loud on store errors
Address reviewer feedback:
- Clear comments when a revised plan is published (save_plan_content) so
feedback on the prior revision doesn't resurface and get re-fed to the agent.
- list_plan_comments gains raise_on_error; approve/reject read comments before
mutating state and propagate store failures (500) instead of silently
dispatching the follow-up run with no feedback.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 18:12:42 -04:00
|
|
|
placeholder="Leave a comment on the plan"
|
|
|
|
|
rows={3}
|
|
|
|
|
className="w-full resize-none rounded-md border border-[var(--ui-border)] bg-[var(--ui-bg)] px-2 py-1.5 text-sm text-[var(--ui-text)] outline-none focus:border-[var(--ui-accent)]"
|
|
|
|
|
/>
|
|
|
|
|
<div className="mt-2 flex justify-end">
|
|
|
|
|
<Button
|
|
|
|
|
data-testid="comment-submit"
|
|
|
|
|
size="sm"
|
|
|
|
|
disabled={posting || !draft.trim()}
|
|
|
|
|
onClick={() => void submitComment()}
|
|
|
|
|
>
|
|
|
|
|
Comment
|
|
|
|
|
</Button>
|
|
|
|
|
</div>
|
|
|
|
|
</div>
|
feat: port plan-review & workflow-approval UX (#159)
* feat: port plan-review & workflow-approval UX (#135)
Port six upstream commits onto dev:
- c03a6be7 (already ported): keep plan guidance high-level
- 546042a4: add workflow approval UI with diff preview, approval URLs,
web review links, and polling for approval status during active runs
- 216cf181: remove workflow token elevation; approved pushes pass
through directly without proxy token rewriting
- 3dbc0282: preserve plan redirects after login by accepting relative
same-origin redirect_to values and rejecting blocked paths
- bb104d93: submit plan comments with cmd+enter
- 90cb6caa: terse Slack replies, shared content via save_plan outside
plan mode (PLAN_STATUS_SHARED), reject shared-content mutations
Refs: #135
* fix: restore login page render and clear CI lint/format
The plan-review port removed the authRedirectUrl import from login.tsx
but left its call site, crashing the login page at runtime (blank page,
no 'Sign in to open-swe'). Pass the relative path straight to loginUrl,
matching the plan route and the backend relative-redirect handling.
Also drop an unused os import in the guard test and reformat
workflow_push_guard.py to satisfy ruff.
* fix: carry workflows:write on the standing proxy token
Complete the half-ported upstream 216cf181 cascade. The port dropped
_run_with_workflow_token from the guard but missed the paired github_app
change, so an approved .github/workflows push ran with the base token
(no workflows:write) and GitHub 403'd it.
Add workflows:write to BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS and delete the
now-orphaned WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant; update the
github_app and proxy_auth tests to match. The HITL approval gate in
workflow_push_guard.py is unchanged — this only lets the standing token
push once a human approves.
* fix: restore transient workflow-token elevation (revert standing workflows:write)
The standing GitHub-App proxy token (BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS) is
ALWAYS-ON, so carrying workflows:write on it made the fork's HITL workflow-push
guard the sole control over unapproved workflow pushes. The guard's git-push
parser has gaps (obfuscated-expansion push, `gh api` REST contents PUT,
fully-qualified cross-branch refspecs); with a permanently workflows-scoped
token those gaps become live unapproved-workflow-push exploits (1 critical, 2
high — security review BLOCK on #159).
Restore dev's transient-elevation model:
- Drop workflows:write from BASE_RUNTIME_PROXY_TOKEN_PERMISSIONS; re-add the
WORKFLOW_RUNTIME_PROXY_TOKEN_PERMISSIONS constant (base + workflows:write).
- Re-introduce _run_with_workflow_token in the guard: it mints the
workflows-scoped token via refresh_proxy_token around the approved,
guard-normalized fixed_command, then downscopes to RUNTIME then BASE in a
finally. Route the approval branch through it.
- Restore the dev token/elevation tests.
The standing token no longer carries workflows:write, so the three parser
bypasses hit GitHub 403 again; an approved push still succeeds because the
elevation grants workflows:write only around the normalized command. Keeps all
of #159's diff-preview / approval-URL / Slack-card guard additions.
* fix: reject protocol-relative path from sanitizeAuthRedirect (open redirect)
sanitizeAuthRedirect returned parsed.pathname+search+hash, which `new URL` can
resolve to a protocol-relative `//host` (e.g. input `/..//evil.com` normalizes
same-origin, passing the origin check, but yields a path starting with `//`).
ClientRedirect / login.tsx feed that path to window.location.replace, so it
navigates cross-origin — an open redirect. Reject any resolved path that is not
a single-leading-slash path (`^/[^/]`), falling back to the default. Adds
coverage for `/..//evil.com`, `/.//evil.com`, and `//evil.com`.
* fix: log SECURITY error when workflow-token downscope fails
The elevate->push->downscope finally block was silent on failure. If both
refresh_proxy_token calls fail, the sandbox retains workflows:write for the
rest of the run with no signal. Log a SECURITY error on the partial and full
downscope-failure paths so the retention is observable.
Addresses the GPT-4.1 cross-family review of the token-scope remediation.
---------
Co-authored-by: amoussa1229 <166072409+amoussa1229@users.noreply.github.com>
Co-authored-by: Adam Moussa <adam@seahavenind.com>
2026-07-09 16:03:13 -04:00
|
|
|
</aside>)}
|
feat: plan mode with model-driven entry and collaborative review (#1580)
* feat: add plan mode for read-only research and planning
Adds a per-run plan_mode flag that puts the agent in a read-only
research phase: a strong prompt section is injected and mutating tools
are stripped via ExcludeToolsMiddleware so the agent proposes a
reviewable implementation plan before any edits. Surfaced in the
dashboard UI with a Plan toggle (Shift+Tab) wired through the thread API.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: enforce plan-mode read-only at tool layer and disable subagents
Addresses PR review: plan mode previously relied on prompt text to keep
the shell read-only and left the task subagent (built with its own
write/PR/Linear tools) unrestricted. Now `task` is excluded so research
cannot be delegated to a mutating subagent, and a new
PlanModeShellGuardMiddleware enforces a read-only command allowlist on
`execute`, blocking writes, git state changes, installs, redirection,
and command substitution regardless of model/prompt-injection compliance.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* fix: harden plan-mode shell guard against wrapped mutations
Block git global options that take values (-C, --git-dir, ...) from being
misread as the subcommand, reject config-injection options (-c,
--config-env, --exec-path), and drop the env command wrapper that could
run arbitrary commands.
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* feat: add plan mode with enter_plan_mode tool, profile/team defaults, Slack commands and approval flow
- enter_plan_mode tool: agent self-activates plan mode via Command(update={'plan_mode': True})
- Plan mode resolution: per-thread > profile default > team default > False
- PLAN_MODE_GUIDANCE_SECTION: always-present prompt section telling agent about the tool
- profile_plan_mode_default and team plan_mode_default settings
- Slack plan on/off/status commands with thread metadata persistence
- slack_thread_reply plan_approval=True renders Approve/Revise/Cancel buttons
- Interactivity handler: approve triggers implementation run, cancel posts confirmation
- Frontend: plan_mode_default in Profile/ProfileUpdate/TeamSettings types and UI toggles
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* test: add tests for enter_plan_mode tool, profile/team defaults, Slack plan commands, approval blocks
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
* refactor(plan-mode): drop shell guard, rely on prompt for read-only discipline
Remove PlanModeShellGuardMiddleware and its enforcement of read-only shell
commands during plan mode. Plan mode now relies on the system prompt to
instruct the agent not to run mutating commands; the mutating-tool exclusion
(ExcludeToolsMiddleware) is retained.
* test(open-swe): add Playwright E2E for the Slack → PR → web handoff
Local, secrets-free end-to-end suite that drives the full happy path through mock Slack/GitHub control panels and the real dashboard UI. Only the LLM and external SaaS HTTP boundaries (GitHub/Slack APIs, OAuth token mint) are faked — the real process_slack_mention, get_agent, deepagents loop, tools, middleware, and dashboard authorization all run under `langgraph dev` with a scripted fake chat model and a local temp-dir sandbox.
- full_flow: a Slack mention runs the agent, which implements a change in the sandbox, opens a PR against a fake GitHub remote, and replies with the PR link in the same thread.
- dashboard: clicking the bot's real "Open in Web" link loads the built ui/ app (served same-origin); the thread owner can continue the conversation, while a different user sees the same thread read-only (no composer).
Wired into Agent CI as a `Playwright E2E` job that runs on pull requests.
* fix(open-swe): serve E2E UI assets via explicit route; pin Playwright
The dashboard E2E served the built ui/ SPA's /assets via app.mount(StaticFiles), but LangGraph's custom-app loader serves APIRoutes and drops sub-app Mounts, so /assets 404'd under `langgraph dev` in CI — the React app never booted and the composer/transcript never rendered. Serve assets via an explicit route instead.
Also pin @playwright/test to the latest (1.61.0) for reproducible runs, and make the owner composer assertion tolerant of either hydration state.
* test(open-swe): record Playwright trace + video on every E2E run
Capture a replayable trace (DOM snapshots, network, console, source) and a screen recording for every test, not just retries, plus a screenshot on failure. The CI job already uploads playwright-report/ and test-results/, so each run now has a downloadable replay; documented how to open it.
* feat(plan-mode): collaborative plan review with BlockNote + Yjs
When the agent enters plan mode it writes the plan as a markdown file in the
sandbox (save_plan tool), publishes it, and posts a review link to the source
channel. Reviewers open the plan inside the dashboard (under the /agents shell),
read it rendered in a BlockNote editor, and leave inline comments synced live
over Yjs. Only the thread owner can approve; any reviewer can request changes.
On approve/reject the comments are harvested and handed to the agent for the
follow-up run; the agent never sees comments mid-review.
- agent: enter_plan_mode persists plan state; new save_plan tool; prompt shares
the plan-review link.
- dashboard: Yjs WebSocket collab server (pycrdt-websocket) with store-backed
snapshots; plan content/status store; plan REST API (get/approve/reject,
owner-only approve, client-harvested comments); planStatus on thread summaries.
- ui: BlockNote native comments (CommentsExtension + YjsThreadStore) plan page
mounted under the agents shell, with a "Review plan" banner in the thread view
and a back-link; theme-aware (dark mode) using the dashboard tokens.
- e2e: Playwright coverage of the full Slack -> plan -> review -> approve -> PR
flow, including cross-user comment sync and owner-only approval.
* fix(plan-mode): address review feedback (authz, overrides, leaks, deps)
- plan-collab WS: authorize per-thread before joining a room (same read gate as
the REST API) — previously any logged-in user could join any thread (IDOR).
- plan-collab: tie the snapshot flusher to active connections (refcount) so each
opened plan no longer leaks a permanent 1.5s task on the shared event loop.
- plan decisions: include thread_id in the follow-up run configurable so the run
resumes the existing thread; set plan_mode explicitly so approve forces it off.
- get_agent: an explicit per-thread plan_mode (Slack `plan off`, approved plan,
dashboard toggle) now overrides profile/team defaults instead of falling back.
- plan mode tool gating moved to a state-aware PlanModeMiddleware installed
unconditionally, so a mid-run enter_plan_mode restricts the next model turn;
before_agent resets stale plan_mode so a later run isn't forced back into it.
- exclude write-capable http_request from plan mode.
- pin pycrdt / pycrdt-websocket with upper bounds.
Includes the latest base (#1583): E2E UI assets served via explicit route
(fixes the Playwright CI failure — LangGraph's app loader drops sub-app mounts).
* style: ruff format plan_collab.py
* fix(plan-mode): owner-gate Slack approval + same-origin check on collab WS
- Slack "Approve & Implement" now verifies the clicking user is the plan
requester (owner, via the stored triggering_user_id) before implementing —
matching the dashboard API's owner-only approval. Non-owners are pointed to
Revise / feedback.
- The plan-collab WebSocket validates the handshake Origin against the dashboard
allowlist before accept() (no-op when unconfigured, e.g. local/dev), mirroring
the REST require_same_origin CSRF defense.
* fix(plan-mode): enter plan mode only via the model + local mock dev harness
Plan mode is now entered solely when the model calls enter_plan_mode.
Removed the per-user and team plan_mode_default settings (backend + UI)
and the Slack `plan on/off/status` toggle.
- enter_plan_mode returns a terminating ToolMessage, fixing the missing
ToolMessage error that silently dropped plan mode mid-run.
- PlanReview: defer Yjs provider/doc teardown so React StrictMode's dev
remount doesn't destroy and then reuse the collaboration provider.
- e2e plan_review spec asserts plan_mode actually engages.
- LangSmith trace-url resolution is best-effort: bail before any API
call when the tenant is unset, cache failures, log at debug.
- Add `pnpm run dev:mock`: same-origin Vite HMR harness with a real LLM,
Alice/Bob mock users, and a GitHub login picker.
* docs(plan-mode): drop stale references to removed profile/team defaults
The plan_mode middleware docstring and the approve/reject dispatch comment
still described the profile/team plan_mode_default resolution that no longer
exists; reword to match model-driven entry + the per-thread carry.
* feat(plan-mode): let any reviewer edit the plan, not just comment
Drop the owner/commenter split for the plan document: everyone with read
access edits and comments alike (DefaultThreadStoreAuth "editor" for all,
editor always editable until a decision, anyone seeds the empty doc). This
matches the collab WS, which already relays frames to every readable user.
Plan approval stays owner-gated.
* test(plan-mode): assert plan-mode entry via the tool's success message
plan_mode lives only in run state for tool gating; it is not a persisted
thread-state channel, so the previous `values.plan_mode === true` poll
could never pass. Assert instead that enter_plan_mode's success ToolMessage
("Plan mode is active …") lands in the thread — which only happens when the
tool's Command applies cleanly, the exact regression this guards.
---------
Co-authored-by: Johannes du Plessis <51395795+johannes117@users.noreply.github.com>
Co-authored-by: open-swe[bot] <open-swe@users.noreply.github.com>
2026-06-23 15:06:58 -04:00
|
|
|
</div>
|
|
|
|
|
</div>
|
|
|
|
|
)
|
|
|
|
|
}
|